Suppr超能文献

巩膜镜在平均角膜上沉降后的过矫验光变化。

Change in over-refraction after scleral lens settling on average corneas.

作者信息

Bray Chelsea, Britton Stephanie, Yeung Debby, Haines Lacey, Sorbara Luigina

机构信息

School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.

出版信息

Ophthalmic Physiol Opt. 2017 Jul;37(4):467-472. doi: 10.1111/opo.12380. Epub 2017 May 12.

Abstract

PURPOSE

The purpose of this study was to determine the change in over-refraction, if any, after a scleral lens settled on the eye for 6-8 h.

METHODS

Sixteen patients of varying refractive errors and normal corneal curvatures (measured with Pentacam Oculus) were fitted with trial Mini-Scleral Design (MSD) scleral lenses (15.8 mm diameter) in one eye. The sagittal depths of the scleral lenses were selected by adding 350 μm to the corneal sagittal heights measured at a chord length of 15 mm with the Visante optical coherence tomographer (OCT) anterior segment scans and picking the closest available trial lens in the set. Initial measurements were taken 30 min after lens insertion and included an auto-refraction, subjective refraction, and best sphere refraction over the contact lens. Visual acuities and Visante OCT anterior segment scans were also taken. These measurements were repeated after 6-8 h of lens wear.

RESULTS

Over the trial wearing period, the average change in the spherical component of the over-refraction was +0.06 D (S.D. 0.17) (p = 0.16). The average change in cylinder was +0.04 D (S.D. 0.19) (p = 0.33). The average absolute change in axis was 1.06° (S.D. 12.11) (p = 0.74). The average change in best sphere was +0.13 ± 0.30 D (p = 0.12). There was no significant change in visual acuity with the best sphere over-refraction over the 6-8 h wearing period. There was a significant change in central corneal clearance over the wearing period of 83 μm (S.D. 22) (p < 0.0001).

CONCLUSION

Despite a significant change in the central corneal clearance due to thinning of the fluid reservoir as the scleral lens settled (an average decrease of 83 μm after wearing the lenses for 6-8 h), there was not a statistically significant change in the subjective over-refraction (sphere, cylinder, and axis) or best sphere or visual acuity. This study has confirmed that there is no link between reduction in central corneal clearance and change in over-refraction for average corneas.

摘要

目的

本研究的目的是确定巩膜镜在眼表停留6 - 8小时后,过矫是否发生变化(若有变化)。

方法

16例屈光不正程度不同但角膜曲率正常(用Pentacam Oculus测量)的患者,一眼佩戴试验性迷你巩膜设计(MSD)巩膜镜(直径15.8毫米)。巩膜镜的矢高通过以下方式选择:用Visante光学相干断层扫描仪(OCT)前段扫描测量15毫米弦长时的角膜矢高,在此基础上加350微米,然后从试验镜片组中挑选最接近的可用试验镜片。镜片插入后30分钟进行初始测量,包括自动验光、主观验光以及接触镜上的最佳球镜验光。同时测量视力和进行Visante OCT前段扫描。镜片佩戴6 - 8小时后重复上述测量。

结果

在试验佩戴期间,过矫的球镜成分平均变化为+0.06 D(标准差0.17)(p = 0.16)。柱镜平均变化为+0.04 D(标准差0.19)(p = 0.33)。轴位平均绝对变化为1.06°(标准差12.11)(p = 0.74)。最佳球镜平均变化为+0.13 ± 0.30 D(p = 0.12)。在6 - 8小时佩戴期间,最佳球镜过矫时视力无显著变化。佩戴期间中央角膜间隙有显著变化,变化量为83微米(标准差22)(p < 0.0001)。

结论

尽管巩膜镜就位时由于储液池变薄导致中央角膜间隙有显著变化(佩戴镜片6 - 8小时后平均减少83微米),但主观过矫(球镜、柱镜和轴位)、最佳球镜或视力并无统计学上的显著变化。本研究证实,对于平均角膜,中央角膜间隙减小与过矫变化之间没有关联。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验