• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

SU-E-T-426: Comparison of HDR Brachytherapy for Cervix Cancer Using an Adaptive Simulated Annealing Program and Oncentra- for Simultaneously Integrated Boost.

作者信息

Yao R, Liao Y, Kiel K, Templeton A, Turian J, Chu J

机构信息

Rush University Medical Center, Chicago, IL.

出版信息

Med Phys. 2012 Jun;39(6Part16):3802-3803. doi: 10.1118/1.4735515.

DOI:10.1118/1.4735515
PMID:28517211
Abstract

PURPOSE

High dose rate (HDR) volumetric brachytherapy is an effective method of treating advanced cervix carcinoma. Local failure is associated with multiple factors including higher maximal standardized uptake value (SUV) values in fluorodeoxyglucose positron emission tomography (FDG- PET) scans. The purpose of this study is to evaluate the ability to simultaneously boost regions of high SUV values using an in-house adaptive simulated annealing (ASA) algorithm and the Oncentra® (Nucletron V.B., Veenendaal, The Netherlands) treatment planning system, thereby potentially improving local control.

METHODS

Five cervix cancers were evaluated for brachytherapy treatment (tandem/ring and/or interstitial needles). MRI and PET images were obtained post-implant and fused with treatment planning CTs to define a high-risk (HR) CTV (cervix and tumor on MRI) and GTV (volume with >50% of the maximum SUV on PET). The prescribed dose was 5-6 Gy to the HR CTV and 7-9 Gy to the GTV. Treatment plans were first generated in Oncentra® with IPSA followed by manual graphic optimization by the physician. Plans were also independently optimized using the ASA program. The two plans were compared side by side and one was chosen for treatment. Dose-volume parameters including D90, V100 of targets, D2cc to the critical organs, and generalized equivalent uniform dose (gEUD) of all structures were compared between the ASA and the Oncentra plans.

RESULTS

Both ASA and Oncentra plans were considered acceptable by the physician in four of five cases. Two ASA plans were chosen due to better critical organ sparing and tumor coverage. Two Oncentra plans were preferred because of lower doses to critical organs. One ASA plan was not accepted because of a higher bowel dose.

CONCLUSIONS

Both ASA and Oncentra® planning methods produce acceptable treatment plans for optimized brachytherapy of cervix carcinoma. Continued studies are warranted to further determine the relative strength of each method. This study was supported in part by a research grant from Varian Medical System Inc.

摘要

相似文献

1
SU-E-T-426: Comparison of HDR Brachytherapy for Cervix Cancer Using an Adaptive Simulated Annealing Program and Oncentra- for Simultaneously Integrated Boost.
Med Phys. 2012 Jun;39(6Part16):3802-3803. doi: 10.1118/1.4735515.
2
Optimization for high-dose-rate brachytherapy of cervical cancer with adaptive simulated annealing and gradient descent.采用自适应模拟退火和梯度下降法对宫颈癌高剂量率近距离放疗进行优化。
Brachytherapy. 2014 Jul-Aug;13(4):352-60. doi: 10.1016/j.brachy.2013.10.013. Epub 2013 Dec 17.
3
SU-E-T-430: Evaluation of Inverse Optimization in Brachytherapy for Locally Advanced Cervix Cancer.
Med Phys. 2012 Jun;39(6Part16):3803. doi: 10.1118/1.4735519.
4
Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy.前列腺高剂量率近距离治疗中逆向计划模拟退火与几何优化的比较。
Brachytherapy. 2004;3(3):147-52. doi: 10.1016/j.brachy.2004.05.007.
5
Dosimetric comparison of volume-based and inverse planning simulated annealing-based dose optimizations for high-dose rate brachytherapy.高剂量率近距离放射治疗中基于体积的剂量优化与基于逆向计划模拟退火的剂量优化的剂量学比较
Med Dosim. 2015 Autumn;40(3):235-9. doi: 10.1016/j.meddos.2015.01.003. Epub 2015 Mar 17.
6
SU-E-T-428: Class Solution for Prostate High Dose Rate Brachytherapy with Inverse Planning Simulated Annealing.SU-E-T-428:采用逆向计划模拟退火的前列腺高剂量率近距离放射治疗的类解决方案
Med Phys. 2012 Jun;39(6Part16):3803. doi: 10.1118/1.4735517.
7
Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans.Oncentra®近距离放疗IPSA与图形优化技术的比较:一项关于高剂量率近距离放疗头颈部及前列腺计划的案例研究
J Med Radiat Sci. 2015 Jun;62(2):168-74. doi: 10.1002/jmrs.107. Epub 2015 May 20.
8
Asymmetric dose-volume optimization with smoothness control for rotating-shield brachytherapy.用于旋转屏蔽近距离放射治疗的具有平滑度控制的非对称剂量体积优化。
Med Phys. 2014 Nov;41(11):111709. doi: 10.1118/1.4897617.
9
Sci-Sat AM: Brachy - 08: MRI-guided planning and maximum achievable HR-CTV doses in cervix brachytherapy.
Med Phys. 2012 Jul;39(7Part4):4646. doi: 10.1118/1.4740215.
10
Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.针对高剂量率近距离放射治疗中导管优化的 CVT 算法的改编。
Med Phys. 2013 Nov;40(11):111724. doi: 10.1118/1.4826335.