Akkuş Özge Güngör, Petriçli Ikbal Seza
Vizyon Eye Surgery and Laser Center, Sırakapılar mah. 495 sok. No:7, Denizli, Turkey.
Department of Ophthalmology, Etlik Zübeyde Hanım Training and Research Hospital, Ankara, Turkey.
Int Ophthalmol. 2018 Jun;38(3):1011-1019. doi: 10.1007/s10792-017-0552-0. Epub 2017 May 18.
To compare the visual acuity outcomes, contrast sensitivity function (CS) and reading ability in patients with bilateral multifocal intraocular lenses and patients with bilateral monofocal lenses.
Vizyon Eye Center, Denizli, Turkey.
Comparative case series.
Consecutive bilateral cataract patients having implantation of Acriva Reviol MFM 611 multifocal IOLs (Group A) or Acriva BB UD 613 monofocal IOLs (Group B) were included. Parameters analyzed 6 months postoperatively included monocular uncorrected distance (UDVA), binocular uncorrected intermediate (UIVA), binocular uncorrected near (UNVA), CS and bilateral reading performance using MN Read.
The study evaluated 42 eyes in Group A and 40 eyes in Group B. There were no statistically significant differences in UDVA between two groups postoperatively (p = .39). Binocular UIVA and binocular UNVA are better in Group A (p = .00, p = .00). Under photopic and scotopic conditions, contrast sensitivity results were decreased in Group A, especially at high spatial frequencies. No statistically difference were found in reading acuity, critical print size and maximum reading speed between two groups (p = .57, p = .62, p = .22).
This study concludes that multifocal lenses are reliable and efficient replacements for reading glasses since they significantly improve the vision for near or intermediate distance activities.
比较双侧多焦点人工晶状体患者与双侧单焦点人工晶状体患者的视力结果、对比敏感度功能(CS)和阅读能力。
土耳其代尼兹利的Vizyon眼科中心。
比较病例系列。
纳入连续的双侧白内障患者,其中一组植入Acriva Reviol MFM 611多焦点人工晶状体(A组),另一组植入Acriva BB UD 613单焦点人工晶状体(B组)。术后6个月分析的参数包括单眼未矫正远视力(UDVA)、双眼未矫正中视力(UIVA)、双眼未矫正近视力(UNVA)、CS以及使用MN Read评估的双侧阅读表现。
该研究评估了A组的42只眼和B组的40只眼。两组术后UDVA无统计学显著差异(p = 0.39)。A组的双眼UIVA和双眼UNVA更好(p = 0.00,p = 0.00)。在明视和暗视条件下,A组对比敏感度结果下降,尤其是在高空间频率时。两组在阅读视力、临界印刷字体大小和最大阅读速度方面未发现统计学差异(p = 0.57,p = 0.62,p = 0.22)。
本研究得出结论,多焦点人工晶状体是阅读眼镜可靠且有效的替代品,因为它们能显著改善近距或中距活动的视力。