Suppr超能文献

肩关节(GHJ)的盲目注射真的比影像引导注射的准确性低吗?一项考虑多种解剖学入路的叙述性系统评价。

Are blind injections of gleno-humeral joint (GHJ) really less accurate imaging-guided injections? A narrative systematic review considering multiple anatomical approaches.

作者信息

Simoni Paolo, Grumolato Marco, Malaise Olivier, Preziosi Marco, Pasleau Francoise, de Lemos Esteves Fréderic

机构信息

Radiology Department, "Reine Fabiola" Children's University Hospital, 15, Avenue Jean Joseph Crocq, 1020, Brussels, Belgium.

Rheumathology Department, Univesity of Liège, Avenue de l'Hopital 11-Bât B34, 4000, Liège, Belgium.

出版信息

Radiol Med. 2017 Sep;122(9):656-675. doi: 10.1007/s11547-017-0772-4. Epub 2017 May 18.

Abstract

AIM

To perform a systematic review to establish whether blind injections of the gleno-humeral (GHJ) joint may be an accurate alternative to injections performed imaging guidance, considering multiple anatomical approaches.

MATERIALS AND METHODS

Our search strategy yielded 478 articles for Scopus, 815 articles for MEDLINE, 128 articles for Cochrane Central Register of Controlled Trials and 555 articles for Embase until May 2016. One hundred and sixty-seven abstracts were retrieved after duplicates removal. Two readers independently reviewed all the 1067 abstracts. They selected for the full-text analysis only the abstracts in which the accuracy of intra-articular position of the needle was confirmed on imaging (humans) or by a surgical dissection (cadavers). Thirty-eight studies were eventually selected for the full-text reading and data extraction. The selected studies included a total of 2309 patients (2690 shoulders) and 195 cadavers (299 shoulders). To objectively assess the methodological quality of the present systematic review, "Assessment of Multiple Systematic Review" (AMSTAR) tool was used.

RESULTS

The overall accuracy of the intra-articular injection in GHJ varied from 42 to 100% in the 38 selected studies. Imaging guidance was used in 65% of articles and the overall accuracy of guided GHJ injections was higher than blind injection. However, five articles in which blind injection the GHJ was used (159 shoulders) reported accuracy as high as 100%.

CONCLUSION

A comprehensive review of the literature confirms that guided injections of the GHJ have overall accuracy higher compared to blind injection. Nevertheless, in some studies, including a relatively large number of shoulders, blind injections have been proven to be 100% accurate. Hence, blind injections of GHJ could be proposed a cost-effective alternative to imaging-guided injection. A large prospective randomized study is needed to gauge this hypothesis and compare the cost-effectiveness of these two techniques for the most common anatomical approaches.

摘要

目的

进行一项系统评价,以确定在考虑多种解剖入路的情况下,肩关节(GHJ)盲注是否可作为影像引导下注射的准确替代方法。

材料与方法

截至2016年5月,我们的检索策略在Scopus数据库中检索到478篇文章,在MEDLINE数据库中检索到815篇文章,在Cochrane对照试验中央注册库中检索到128篇文章,在Embase数据库中检索到555篇文章。去除重复后检索到167篇摘要。两名读者独立审阅了所有1067篇摘要。他们仅选择那些经影像学(人体)或手术解剖(尸体)证实针在关节内位置准确性的摘要进行全文分析。最终选择了38项研究进行全文阅读和数据提取。所选研究共纳入2309例患者(2690个肩部)和195具尸体(299个肩部)。为客观评估本系统评价的方法学质量,使用了 “多种系统评价评估”(AMSTAR)工具。

结果

在38项所选研究中,GHJ关节内注射的总体准确率在42%至100%之间。65%的文章使用了影像引导,影像引导下GHJ注射的总体准确率高于盲注。然而,有五篇使用GHJ盲注的文章(159个肩部)报告准确率高达100%。

结论

对文献的全面综述证实,与盲注相比,影像引导下的GHJ注射总体准确率更高。然而,在一些研究中,包括相当数量的肩部,盲注已被证明准确率为100%。因此,GHJ盲注可作为影像引导注射的一种经济有效的替代方法。需要进行一项大型前瞻性随机研究来验证这一假设,并比较这两种技术在最常见解剖入路中的成本效益。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验