Craciun Laura, Alving Jørgen, Gardella Elena, Terney Daniella, Meritam Pirgit, Cacic Hribljan Melita, Beniczky Sándor
Department of Clinical Neurophysiology, Danish Epilepsy Center, Dianalund, Denmark.
Department of Clinical Neurophysiology, Danish Epilepsy Center, Dianalund, Denmark; Department of Clinical Neurophysiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Seizure. 2017 Jul;49:13-16. doi: 10.1016/j.seizure.2017.05.006. Epub 2017 May 13.
To assess whether injuries occur more often in an Epilepsy Monitoring Unit (EMU) where portable EEG amplifiers are used, and where patients can freely move within a large area during the monitoring.
Patients were monitored at the Danish Epilepsy Center, in an EMU specifically designed for this purpose, and they were under continuous surveillance by personnel dedicated to the EMU. Adverse events (AEs) - including injuries, were prospectively noted, as part of the safety policy of the hospital. Other data were retrospectively extracted from the electronic database, for a 5-year period (January 2012-December 2016).
976 patients were admitted to the EMU. Falls occurred in 19 patients (1.9%) but none of them resulted in injury. Only one serious AE occurred: a patient had a convulsive status epilepticus, which did not respond to first-line treatment in the EMU and was transferred to the intensive care unit. The rate of AEs were similar or lower than previously reported by other centers, where the mobility of the patients had been restricted during monitoring.
In an EMU specially designed for this purpose, where patients are under continuous surveillance by personnel dedicated to the EMU, injuries can be avoided even when the mobility of the patients is not restricted.
评估在使用便携式脑电图放大器且患者在监测期间可在大面积区域自由活动的癫痫监测单元(EMU)中,伤害事件是否更频繁发生。
患者在丹麦癫痫中心专门为此设计的EMU中接受监测,且由该EMU的专职人员进行持续监视。作为医院安全政策的一部分,前瞻性记录不良事件(AE),包括伤害事件。其他数据从电子数据库中进行回顾性提取,为期5年(2012年1月至2016年12月)。
976例患者入住EMU。19例患者(1.9%)发生跌倒,但均未导致受伤。仅发生1例严重AE:1例患者出现癫痫持续状态,在EMU中对一线治疗无反应,被转至重症监护病房。AE发生率与其他中心先前报告的相似或更低,在其他中心,患者在监测期间的活动受到限制。
在专门为此设计的EMU中,患者由EMU专职人员进行持续监视,即使患者活动不受限制,也可避免伤害发生。