Pérez-Castilla Alejandro, Feriche Belén, Jaric Slobodan, Padial Paulino, García-Ramos Amador
1 University of Granada.
2 University of Delaware.
J Appl Biomech. 2017 Oct 1;33(5):388-392. doi: 10.1123/jab.2016-0142. Epub 2017 Sep 19.
This study aimed to examine the validity of mechanical variables obtained by a linear velocity transducer from the unconstrained and constrained squat jump (SJ). Twenty-three men were tested on the unconstrained SJ and the SJ constrained by a Smith machine. Maximum values of force, velocity, and power were simultaneously recorded both by a linear velocity transducer attached to a bar of mass of 17, 30, 45, 60, and 75 kg and by a force plate. Linear velocity transducer generally overestimated the outcomes measured as compared to the force plate, particularly in unconstrained SJ. Bland-Altman plots revealed that heteroscedasticity of errors was mainly observed for velocity variables (r = .26-.58) where the differences were negatively associated with the load magnitude. However, exceptionally high correlations were observed between the same outcomes recorded with the 2 methods in both unconstrained (median r = .89 [.71-.95]) and constrained SJ (r = .90 [.65-.95]). Although the systematic and proportional bias needs to be acknowledged, the high correlations between the variables obtained by 2 methods suggest that the linear velocity transducer could provide valid values of the force, velocity, and power outputs from both unconstrained and constrained SJ.
本研究旨在检验线性速度传感器在无约束和有约束深蹲跳(SJ)中所获取力学变量的有效性。对23名男性进行了无约束SJ和受史密斯机约束的SJ测试。通过连接在质量为17、30、45、60和75千克杠铃杆上的线性速度传感器以及测力台,同时记录力、速度和功率的最大值。与测力台相比,线性速度传感器通常高估了测量结果,尤其是在无约束SJ中。布兰德-奥特曼图显示,误差的异方差性主要出现在速度变量上(r = 0.26 - 0.58),其中差异与负荷大小呈负相关。然而,在无约束(中位数r = 0.89 [0.71 - 0.95])和有约束SJ(r = 0.90 [0.65 - 0.95])中,两种方法记录的相同结果之间均观察到极高的相关性。尽管需要认识到存在系统偏差和比例偏差,但两种方法所获变量之间的高相关性表明,线性速度传感器能够提供无约束和有约束SJ中力、速度和功率输出的有效值。