Suppr超能文献

肌强直测量法可可靠地测量大鱼际肌和会阴肌的肌肉僵硬度。

Myotonometry Reliably Measures Muscle Stiffness in the Thenar and Perineal Muscles.

作者信息

Davidson Melissa J, Bryant Adam L, Bower Wendy F, Frawley Helena C

机构信息

Remarkable Physios Ltd., Queenstown, New Zealand.

Department of Physiotherapy, Faculty of Medicine, Dentistry, and Health Sciences, The University of Melbourne.

出版信息

Physiother Can. 2017;69(2):104-112. doi: 10.3138/ptc.2015-85.

Abstract

The authors investigated the reliability of myotonometry-measured muscle tone in the thenar and perineal muscles. Participants were women aged 18-50 years who were asymptomatic for thumb and pelvic floor dysfunction (interrater study =20; intrarater study =43) or who were symptomatic for vulvodynia (interrater study =14; intrarater study =32). Mechanical properties (stiffness, frequency, decrement, relaxation time, and creep) of the muscles were measured using a myotonometer (MyotonPRO) while the muscles were in a relaxed state. Measures were performed twice by two assessors. Intra- and interrater reliability were determined using intra-class correlation coefficients (ICCs) and absolute reliability using the standard error of measurement and a minimum detectable change. The primary property of interest, muscle stiffness, showed very good interrater (ICC 0.85-0.86) and intrarater (ICC 0.82-0.88) reliability in the thenar eminence. In the perineal muscles, reliability results ranged from good to very good for interrater (ICC 0.70-0.86) and intrarater (ICC 0.80-0.91) reliability for muscle stiffness. Absolute reliability was confirmed, with all measures showing minimal variance. Muscle stiffness of the smaller muscles of the body can be reliably measured using the MyotonPRO. The device could be used as a reference standard in the development of a digital palpation scale that would facilitate accurate diagnosis of muscle tone.

摘要

作者研究了用肌张力计测量的大鱼际肌和会阴肌肌张力的可靠性。参与者为18至50岁的女性,她们没有拇指和盆底功能障碍的症状(评估者间研究=20;评估者内研究=43),或者有外阴痛症状(评估者间研究=14;评估者内研究=32)。在肌肉处于放松状态时,使用肌张力计(MyotonPRO)测量肌肉的力学特性(刚度、频率、衰减、松弛时间和蠕变)。两名评估者各进行两次测量。使用组内相关系数(ICC)确定评估者内和评估者间的可靠性,使用测量标准误差和最小可检测变化确定绝对可靠性。主要关注的特性——肌肉刚度,在大鱼际肌中显示出非常好的评估者间(ICC 0.85 - 0.86)和评估者内(ICC 0.82 - 0.88)可靠性。在会阴肌中,肌肉刚度的评估者间(ICC 0.70 - 0.86)和评估者内(ICC 0.80 - 0.91)可靠性结果从良好到非常好不等。绝对可靠性得到证实,所有测量显示出最小的差异。使用MyotonPRO可以可靠地测量身体较小肌肉的肌肉刚度。该设备可作为数字触诊量表开发中的参考标准,有助于准确诊断肌张力。

相似文献

6
Myotonometer intra- and interrater reliabilities.肌张力测量仪的内部和外部评估者信度。
Arch Phys Med Rehabil. 2003 Jun;84(6):928-32. doi: 10.1016/s0003-9993(03)00006-6.

引用本文的文献

本文引用的文献

10
Accuracy of concepts in female pelvic floor anatomy: facts and myths!女性盆底解剖学概念的准确性:事实与误区!
World J Urol. 2012 Aug;30(4):429-35. doi: 10.1007/s00345-011-0777-x. Epub 2011 Oct 15.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验