Suppr超能文献

两种接骨板构型用于猫下颌骨简单横行尾侧骨折模型固定的生物力学评估

Biomechanical evaluation of two plating configurations for fixation of a simple transverse caudal mandibular fracture model in cats.

作者信息

Greiner Christopher L, Verstraete Frank J M, Stover Susan M, Garcia Tanya C, Leale Dustin, Arzi Boaz

出版信息

Am J Vet Res. 2017 Jun;78(6):702-711. doi: 10.2460/ajvr.78.6.702.

Abstract

OBJECTIVE To evaluate biomechanical properties of intact feline mandibles, compared with those for mandibles with an experimentally created osteotomy that was stabilized with 1 of 2 internal fixation configurations. SAMPLE 20 mandibles from 10 adult feline cadavers. PROCEDURES An incomplete block study design was used to assign the mandibles of each cadaver to 2 of 3 groups (locking plate with locking screws [locking construct], locking plate with nonlocking screws [nonlocking construct], or intact). Within each cadaver, mandibles were randomly assigned to the assigned treatments. For mandibles assigned to the locking and nonlocking constructs, a simple transverse osteotomy was created caudal to the mandibular first molar tooth after plate application. All mandibles were loaded in cantilever bending in a single-load-to-failure test while simultaneously recording load and actuator displacement. Mode of failure (bone or plate failure) was recorded, and radiographic evidence of tooth root and mandibular canal damage was evaluated. Mechanical properties were compared among the 3 groups. RESULTS Stiffness, bending moments, and most post-yield energies for mandibles with the locking and nonlocking constructs were significantly lower than those for intact mandibles. Peak bending moment and stiffness for mandibles with the locking construct were significantly greater than those for mandibles with the nonlocking construct. Mode of failure and frequency of screw damage to tooth roots and the mandibular canal did not differ between the locking and nonlocking constructs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that both fixation constructs were mechanically inferior to intact mandibles. The locking construct was mechanically stronger than the nonlocking construct.

摘要

目的 评估完整猫下颌骨的生物力学特性,并与采用两种内固定配置之一进行稳定固定的实验性截骨下颌骨的生物力学特性进行比较。样本 来自 10 只成年猫尸体的 20 个下颌骨。方法 采用不完全区组研究设计,将每具尸体的下颌骨分配到 3 组中的 2 组(带锁定螺钉的锁定钢板 [锁定结构]、带非锁定螺钉的锁定钢板 [非锁定结构] 或完整组)。在每具尸体中,下颌骨被随机分配到指定的治疗组。对于分配到锁定和非锁定结构组的下颌骨,在应用钢板后,于下颌第一磨牙后方制作一个简单的横向截骨术。所有下颌骨在单载荷至破坏试验中进行悬臂弯曲加载,同时记录载荷和致动器位移。记录破坏模式(骨或钢板破坏),并评估牙根和下颌管损伤的影像学证据。比较 3 组之间的力学性能。结果 锁定和非锁定结构下颌骨的刚度、弯矩以及大多数屈服后能量均显著低于完整下颌骨。锁定结构下颌骨的峰值弯矩和刚度显著大于非锁定结构下颌骨。锁定和非锁定结构之间的破坏模式以及螺钉对牙根和下颌管的损伤频率没有差异。结论及临床意义 结果表明,两种固定结构在力学性能上均低于完整下颌骨。锁定结构在力学上比非锁定结构更强。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验