Suppr超能文献

猫下颌骨骨折采用可吸收植入物或口内夹板固定后的力学评估

Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats.

作者信息

Castejon-Gonzalez Ana C, Friday Chet S, Hast Michael W, Reiter Alexander M

机构信息

Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United States.

Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, United States.

出版信息

Front Vet Sci. 2025 Jan 7;11:1525586. doi: 10.3389/fvets.2024.1525586. eCollection 2024.

Abstract

INTRODUCTION

The goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring plus bis-acryl composite intraoral splint (S); (2) modified Risdon interdental wiring plus bis-acryl composite intraoral splint (R); (3) ultrasound-aided absorbable fixation plate (P); and (4) ultrasound-aided absorbable fixation mesh (M).

MATERIALS AND METHODS

Thirty feline mandibles were randomly assigned to the control and treatment groups. Mandibles were loaded by cantilever bending on the canine tooth, first in non-destructive cyclic loading followed by destructive ramp-to-failure loading.

RESULTS

Cyclic loading showed no differences between the treatment groups in angular deflection (a measure of sample flexion under non-destructive loads); however, the R group had significantly higher angular deflection than the C group. In destructive testing, no differences in mechanical properties were found between the treatment groups; however, all treatment groups demonstrated significantly lower maximum bending moment, bending stiffness, energy to failure, and maximum force when compared to the control group. The main mode of failure of the intraoral splint groups (S and R) was fracture of the bis-acryl composite (50%), and the main mode of failure of the absorbable fixation groups (P and M) was fracture of the pins (91.7%).

DISCUSSION

Intraoral splint and absorbable fixation methods have low strength and stiffness. The four treatments tested provided similar stabilization of mandibular fractures located between the third and fourth premolar teeth.

摘要

引言

本猫尸体研究的目的是比较完整下颌骨(C组)与模拟骨折位于第三和第四前磨牙之间并采用四种可能治疗方法修复的下颌骨的力学性能:(1)坚固的多环牙间结扎加双丙烯酸复合口腔内夹板(S组);(2)改良的里斯登牙间结扎加双丙烯酸复合口腔内夹板(R组);(3)超声辅助可吸收固定板(P组);(4)超声辅助可吸收固定网(M组)。

材料与方法

30个猫下颌骨随机分为对照组和治疗组。通过在犬齿上进行悬臂弯曲加载下颌骨,首先进行无损循环加载,然后进行破坏性斜坡至破坏加载。

结果

循环加载显示治疗组之间在角偏转(无损载荷下样本弯曲的一种度量)方面没有差异;然而,R组的角偏转明显高于C组。在破坏性测试中,治疗组之间在力学性能上没有差异;然而,与对照组相比,所有治疗组的最大弯矩、弯曲刚度、破坏能量和最大力均显著降低。口腔内夹板组(S组和R组)的主要失效模式是双丙烯酸复合材料断裂(50%),可吸收固定组(P组和M组)的主要失效模式是销钉断裂(91.7%)。

讨论

口腔内夹板和可吸收固定方法的强度和刚度较低。所测试的四种治疗方法对位于第三和第四前磨牙之间的下颌骨骨折提供了相似的稳定性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ebf4/11784150/d4fa4c9937cc/fvets-11-1525586-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验