Suppr超能文献

不同浓度氢氟酸蚀刻后长石质陶瓷冠的疲劳失效负荷。

Fatigue failure load of feldspathic ceramic crowns after hydrofluoric acid etching at different concentrations.

机构信息

Doctoral student, Graduate Program in Oral Science, Prosthodontics Unit, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil.

Adjunct Professor, Graduate Program in Oral Science, Prosthodontics Unit, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil.

出版信息

J Prosthet Dent. 2018 Feb;119(2):278-285. doi: 10.1016/j.prosdent.2017.03.021. Epub 2017 May 26.

Abstract

STATEMENT OF PROBLEM

Hydrofluoric acid etching modifies the cementation surface of ceramic restorations, which is the same surface where failure is initiated. Information regarding the influence of hydrofluoric acid etching on the cyclic loads to failure of ceramic crowns is lacking.

PURPOSE

The purpose of this in vitro study was to evaluate the influence of different hydrofluoric acid concentrations on the fatigue failure loads of feldspathic ceramic crowns.

MATERIAL AND METHODS

Eighty feldspathic ceramic crowns were cemented with resin cement to identical simplified complete crown preparations machined in a dentin-like polymer. The preparations were etched with 10% hydrofluoric acid for 60 seconds and received a primer coating. Before cementation, the intaglio of the ceramic crowns was treated with 1 of 4 surface conditionings (n=20): nonconditioned (control, CTRL), or etched for 60 seconds with different hydrofluoric acid concentrations: 1% (HF1), 5% (HF5), and 10% (HF10). A silane coupling agent was applied on this surface of all crowns, which were cemented to the preparations. Each crown was cyclically loaded in water with a G10 epoxy-glass piston positioned in the center of the occlusal surface. Fatigue failure loads of ceramic crowns were obtained by the staircase approach after 500000 cycles at 20 Hz. Mean failure loads were analyzed by 1-way ANOVA and the Tukey test (α=.05).

RESULTS

Mean failure loads of groups CTRL (245.0 ±15.1 N), HF1 (242.5 ±24.7 N), and HF10 (255.7 ±53.8 N) were statistically similar (P>.05), while that of the HF5 group (216.7 ±22.5 N) was significantly lower (P<.05).

CONCLUSIONS

HF5 acid had a negative effect on the fatigue loads of the tested feldspathic ceramic crowns, while HF1 and HF10 acids did not change the fatigue resistance.

摘要

问题陈述

氢氟酸蚀刻改变了陶瓷修复体的粘结表面,而正是这个表面引发了失效。关于氢氟酸蚀刻对陶瓷冠循环失效负荷的影响的信息尚不清楚。

目的

本体外研究的目的是评估不同浓度氢氟酸对长石陶瓷冠疲劳失效负荷的影响。

材料和方法

将 80 个长石陶瓷冠用树脂水泥粘结到在类牙本质聚合物中加工的相同简化全冠预备体上。预备体用 10%氢氟酸蚀刻 60 秒,并进行底漆涂层处理。在粘结前,陶瓷冠的凹面用以下 4 种表面处理方法中的 1 种处理(n=20):未处理(对照,CTRL)或用不同浓度的氢氟酸蚀刻 60 秒:1%(HF1)、5%(HF5)和 10%(HF10)。所有冠的凹面均涂有硅烷偶联剂,然后粘结到预备体上。每个冠都在水中用 G10 环氧玻璃活塞置于牙合面中心进行循环加载。经过 20 Hz、50 万次循环后,采用阶梯法获得陶瓷冠的疲劳失效负荷。采用单因素方差分析和 Tukey 检验(α=.05)对平均失效负荷进行分析。

结果

CTRL 组(245.0 ±15.1 N)、HF1 组(242.5 ±24.7 N)和 HF10 组(255.7 ±53.8 N)的平均失效负荷统计学上相似(P>.05),而 HF5 组(216.7 ±22.5 N)的平均失效负荷显著较低(P<.05)。

结论

HF5 酸对测试的长石陶瓷冠的疲劳负荷有负面影响,而 HF1 和 HF10 酸没有改变其疲劳抗力。