Suppr超能文献

修复前磨牙的疲劳破坏载荷:不同浓度氢氟酸蚀刻陶瓷嵌体凹面的影响。

Fatigue Failure Load of Restored Premolars: Effect of Etching the Intaglio Surface of Ceramic Inlays With Hydrofluoric Acid at Different Concentrations.

作者信息

Missau T, Venturini A B, Pereira Gkr, Prochnow C, Valandro L F, Rippe M P

出版信息

Oper Dent. 2018 Mar/Apr;43(2):E81-E91. doi: 10.2341/16-345-L.

Abstract

The aim of this study was to evaluate the effect of etching, with different hydrofluoric acid concentrations at the intaglio surface of feldspathic ceramic inlays, on the fatigue failure load of restored premolars. A total of 60 upper premolars were embedded in plastic cylinders with acrylic resin (up to 3 mm below the cement-enamel junction) and prepared using a device specially designed for that purpose. Teeth were randomly assigned to three groups (n=20): HF1, HF5, and HF10 (etching with hydrofluoric acid for 60 seconds at concentrations of 1%, 5%, and 10%, respectively). Preparations were scanned and restorations were milled by a computer-aided design / computer-aided manufacturing system. The inner surfaces of the inlays were etched and received an application of a silane coupling agent; the dentin and enamel were treated appropriately for the luting system (RelyX ARC, 3M-ESPE). The restorations were cemented and the fatigue failure load (in N) was determined using the staircase method (10 Hz; 10 cycles in each step). The initial load (585.5 N) was applied on the slopes of the cusps (labial and palatal/lingual, simultaneously) through a cylinder attached to the test machine (Instron ElectroPuls E3000). The tested samples were analyzed under a stereomicroscope for failure analysis. Fatigue data were analyzed by one-way analysis of variance. There was no statistical difference among the fatigue failure loads (in N): HF1 (448.5±79.1), HF5 (360.7±55.4), and HF10 (409.5±121.1). Regarding the fracture mode, there was a predominance of interfacial fracture (50%), followed by cusp fracture (34.6%). It may be concluded that the etching with hydrofluoric acid at the tested concentrations (1%, 5%, and 10%) does not influence the fatigue failure load of feldspathic ceramic inlays cemented on premolars.

摘要

本研究的目的是评估在长石质陶瓷嵌体的凹面使用不同氢氟酸浓度进行酸蚀,对修复前磨牙疲劳破坏载荷的影响。总共60颗上颌前磨牙用丙烯酸树脂嵌入塑料圆柱体中(至牙骨质 - 釉质界下方3毫米处),并使用为此专门设计的设备进行预备。牙齿被随机分为三组(n = 20):HF1组、HF5组和HF10组(分别用1%、5%和10%的氢氟酸酸蚀60秒)。对预备体进行扫描,并用计算机辅助设计/计算机辅助制造系统制作修复体。对嵌体的内表面进行酸蚀并施加硅烷偶联剂;对牙本质和釉质进行适当处理以适应粘接系统(RelyX ARC,3M-ESPE)。将修复体粘接,并用阶梯法(10赫兹;每步10个循环)测定疲劳破坏载荷(单位为牛顿)。通过连接到测试机(Instron ElectroPuls E3000)的圆柱体,在牙尖斜面(唇面和腭面/舌面,同时施加)施加初始载荷(585.5牛顿)。在体视显微镜下对测试样本进行分析以进行失效分析。疲劳数据采用单因素方差分析。疲劳破坏载荷(单位为牛顿)在HF1组(448.5±79.1)、HF5组(360.7±55.4)和HF10组(409.×121.1)之间无统计学差异。关于断裂模式,界面断裂占主导(50%),其次是牙尖断裂(34.6%)。可以得出结论,在所测试的浓度(1%、5%和10%)下用氢氟酸酸蚀不会影响粘接在上颌前磨牙上的长石质陶瓷嵌体的疲劳破坏载荷。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验