Chen Liang-Wan, Wu Xi-Jie, Cao Hua, Dai Xiao-Fu
Department of Cardiac Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, 350001, China.
J Cardiothorac Surg. 2017 Jun 5;12(1):46. doi: 10.1186/s13019-017-0593-5.
To reduce some problems of traditional graft, we devise a modified multiple branched graft for repair of Crawford extent II and III thoracoabdominal aortic aneurysm (TAAA).
We described a modified multiple branched graft for Crawford extent II and III thoracoabdominal aortic aneurysm (TAAA) repair in 8 patients, Which comprised a main graft and three branches, and the third branch was bifurcated into two limbs.
Our initial experience demonstrated that this modified multiple branched graft may make the thoracoabdominal aortic aneurysm(TAAA) repair easier and safer.
为减少传统移植物的一些问题,我们设计了一种改良的多分支移植物,用于修复克劳福德Ⅱ型和Ⅲ型胸腹主动脉瘤(TAAA)。
我们描述了一种用于修复8例克劳福德Ⅱ型和Ⅲ型胸腹主动脉瘤(TAAA)的改良多分支移植物,它由一个主移植物和三个分支组成,第三个分支分叉为两个分支。
我们的初步经验表明,这种改良的多分支移植物可能会使胸腹主动脉瘤(TAAA)的修复更容易、更安全。