Müller H, Heinrich M, Mielenz N, Reese S, Steiner A, Starke A
Clinic for Ruminants and Swine, Faculty of Veterinary Medicine, University of Leipzig, An den Tierkliniken 11, 04103, Leipzig, Germany.
Institute for Agriculture and Nutrition, Biometrics and Informatics in Agriculture Group, Martin-Luther-University, Karl-Freiherr-von-Fritsch-Straße 4, 06120, Halle (Saale), Germany.
BMC Vet Res. 2017 Jun 6;13(1):162. doi: 10.1186/s12917-017-1090-8.
Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation.
A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles.
Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.
局部循环障碍被认为与牛足部疾病的发生有关。本研究的目的是使用脉冲波(PW)多普勒超声评估两后肢跗关节区域趾间动脉的适用性,并研究奶牛该部位的动脉血流定量变量。使用配备10MHz线性探头的百胜MyLabOne超声仪评估22头健康德国荷斯坦奶牛两后肢跗关节区域趾间动脉的血流情况。这些奶牛来自三个商业农场,在未使用镇静剂的情况下被限制在站立式蹄修整斜槽中。
22头奶牛中有17头获得了适合分析的PW多普勒信号。血流曲线分为四种类型,并在三个均匀心动周期中测量以下定量变量:血管直径、脉搏率、最大收缩速度、最大舒张速度、舒张末期速度、反向速度、最大时间平均平均速度、血流速率、阻力指数和持续性指数。来自三个农场的奶牛之间的测量结果没有差异。最大收缩速度、血管直径和脉搏率没有差异,但不同血流曲线之间的其他变量有显著差异。
负重差异被认为是健康奶牛血流曲线正常变异性的原因。本报告中用于评估趾间动脉血流的扫描技术似乎适用于对健康奶牛和跛行奶牛的进一步研究。