McGrattan Katlyn E, McFarland David H, Dean Jesse C, Hill Elizabeth, White David R, Martin-Harris Bonnie
Department of Health Sciences and Research, Medical University of South Carolina, Charleston.
Faculties of Medicine, Université de Montréal and McGill University, Montréal, Québec, Canada.
Am J Speech Lang Pathol. 2017 Aug 15;26(3):832-839. doi: 10.1044/2017_AJSLP-16-0052.
Single-use, laser-cut, slow-flow nipples were evaluated for their effect on respiration and milk ingestion in 13 healthy preterm infants (32.7-37.1 weeks postmenstrual age) under nonlaboratory, clinical conditions.
The primary outcomes of minute ventilation and overall milk transfer were measured by using integrated nasal airflow and volume-calibrated bottles during suck bursts and suck burst breaks during slow-flow and standard-flow nipple bottle feedings. Wilcoxon signed-ranks tests were used to test the effect of nipple type on both outcomes.
Prefeeding minute ventilation decreased significantly during suck bursts and returned to baseline values during suck burst breaks across both slow-flow and standard-flow nipples. No differences were found in minute ventilation (p > .40) or overall milk transfer (p = .58) between slow-flow and standard-flow nipples.
The lack of difference in primary outcomes between the single-use slow-flow and standard-flow nipples may reflect variability in nipple properties among nipples produced by the same manufacturer. Future investigations examining the effect of both single-use and reusable nipple products are warranted to better guide nipple selection during clinical care.