Wang Ling, Li Qiang, Wang Xi-Ming, Hao Guang-Yu, Hu Su, Hu Chun-Hong
Department of Radiology, The First Affiliated Hospital of Soochow University, No. 188, Street of Ten Catalpa, Suzhou, 200000, China.
Department of Radiology, The First Affiliated Hospital of Soochow University, No. 188, Street of Ten Catalpa, Suzhou, 200000, China; Department of Radiology, Yinzhou Hospital, Ningbo University, No. 251, East of Baizhang Road, Ningbo, 315100, China.
Eur J Radiol. 2017 Jul;92:72-77. doi: 10.1016/j.ejrad.2017.04.005. Epub 2017 Apr 10.
To access the effect of iodinate contrast agent (ICA) on DNA double-stand breaks (DSBs) in human peripheral blood lymphocytes during computed tomography (CT) examinations.
This present study was approved by the institutional ethics committee; written informed patient consent was obtained from 70 patients. A total of 48 patients underwent computed tomography urography (CTU), in which only one time CT scanning was examined after injecting ICA, and 22 patients received unenhanced whole abdominal CT, among them 10 patients were selected to get ICA injection immediately after irradiation. Blood samples were taken from all patients prior to and immediately after CT scan, as well as 8min after the injection of ICA. The lymphocytes in these blood samples were separated by using density-gradient centrifugation, fixed and immunostained with γH2AX antibody. The average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was counted under a fluorescence microscopy. Differences in the number of γH2AX-foci were statistically analyzed using independent sample t test and one way ANOVA.
The three patient groups had no significant differences in the baseline foci numbers(P>0.05). The γH2AX-focus levels increased in both groups after CT scan. Patients who underwent CTU examinations had a greater DSBs level (mean±standard error of mean, 0.945±0.184 foci per cell) than those who received unenhanced whole abdominal CT scan (mean±standard error of mean, 0.700±0.112 foci per cell), increasing by about 37.9%; The ICA injected before CT scan itself had an effect on the DSBs, which increased DSBs level by approximately 90.3% (0.059±0.018vs 0.031±0.025, P<0.05), but no significant difference was found if added after irradiation, increasing DSBs level only by 3.2% approximately (0.711±0.091vs 0.689±0.108, P=0.499).
The iodinated contrast agent itself can lead to an increase in the level of DSBs as assessed with γH2AX foci formation, and the application of ICA can amplify DNA damage induced by diagnostic x-ray procedures such as whole abdominal CT.
探讨在计算机断层扫描(CT)检查期间,碘化造影剂(ICA)对人外周血淋巴细胞DNA双链断裂(DSB)的影响。
本研究经机构伦理委员会批准;获得了70例患者的书面知情同意书。48例患者接受了计算机断层扫描尿路造影(CTU),其中注射ICA后仅进行了一次CT扫描,22例患者接受了全腹部平扫CT,其中10例患者在照射后立即注射ICA。在CT扫描前、扫描后即刻以及注射ICA后8分钟采集所有患者的血样。使用密度梯度离心法分离这些血样中的淋巴细胞,固定并用γH2AX抗体进行免疫染色。在荧光显微镜下计数每个淋巴细胞中磷酸化组蛋白H2AX(γH2AX)灶的平均数。使用独立样本t检验和单因素方差分析对γH2AX灶数量的差异进行统计学分析。
三组患者的基线灶数无显著差异(P>0.05)。CT扫描后两组的γH2AX灶水平均升高。接受CTU检查的患者的DSB水平(平均±平均标准误,每细胞0.945±0.184个灶)高于接受全腹部平扫CT扫描的患者(平均±平均标准误,每细胞0.700±0.112个灶),增加了约37.9%;CT扫描前注射的ICA本身对DSB有影响,使DSB水平增加了约90.3%(0.059±0.018对0.031±0.025,P<0.05),但照射后添加则无显著差异,仅使DSB水平增加了约3.2%(0.711±0.091对0.689±0.108,P=0.499)。
以γH2AX灶形成评估,碘化造影剂本身可导致DSB水平升高,且ICA的应用可放大诊断性X线检查如全腹部CT所致的DNA损伤。