Abstract

INTRODUCTION

Denture disinfection is an indispensable procedure for preventing cross contamination and the maintenance of a healthy oral mucosa in patients rehabilitated with removable dental prosthesis. Nevertheless, they are known to cause changes in the physical and mechanical properties of denture base resins and acrylic resin denture teeth following immersion of a denture in a suitable chemical disinfectant solution or by undergoing microwave irradiation. One such mechanical property indicator for artificial tooth materials is hardness.

AIM

To assess the surface hardness of acrylic resin teeth of three different commercial brands (Ivoclar, Newace, Acryrock) following chemical (2% glutaraldehyde, 1% sodium hypochlorite) and microwave disinfections.

MATERIALS AND METHODS

Ten specimens of each of the three commercial brands were made for control and each simulated disinfection type and stored in distilled water at room temperature for 24 hours. After water storage, specimens were immersed in 2% glutaraldehyde and 1% sodium hypochlorite (one and three cycles) at room temperature for 10 minutes. Irradiation with microwave (one and three cycles) was done in domestic microwave for three minutes with the specimens immersed in 150 ml of distilled water. The specimens were stored in distilled water at room temperature for seven days after each disinfection cycle. Vickers hardness measurements were made using a hardness indenter under a load of 50 g force for 10 seconds. Data was subjected to repeated measure two-way ANOVA test and Tukey's test.

RESULTS

There were statistically significant differences for the variables disinfection, tooth, and cycle (p<0.05 for teeth & disinfectant interaction, p<0.05 cycle and disinfectant interaction). The mean surface hardness following one microwave disinfection cycle was lower than control, glutaraldehyde and sodium hypochlorite. Comparison among cycles revealed that microhardness was significantly decreased for three cycles of microwave disinfection.

CONCLUSION

It was concluded that there was no significant difference in microhardness when the teeth were subjected to chemical disinfection but three cycles of microwave disinfection produced decrease in the microhardness of different types of artificial teeth.

摘要

引言

义齿消毒是预防交叉污染以及维护佩戴可摘义齿患者口腔黏膜健康的一项必不可少的程序。然而,众所周知,将义齿浸泡在合适的化学消毒溶液中或进行微波照射后,义齿基托树脂和丙烯酸树脂义齿牙的物理和机械性能会发生变化。人工牙材料的一种此类机械性能指标就是硬度。

目的

评估三种不同商业品牌(义获嘉、新亚齿、雅定)的丙烯酸树脂牙在化学消毒(2%戊二醛、1%次氯酸钠)和微波消毒后的表面硬度。

材料与方法

为对照以及每种模拟消毒类型制作三种商业品牌中每个品牌的十个样本,并在室温下于蒸馏水中储存24小时。储水后,将样本在室温下浸泡于2%戊二醛和1%次氯酸钠中(一个和三个循环)10分钟。在样本浸泡于150毫升蒸馏水中的情况下,使用家用微波炉进行微波照射(一个和三个循环)三分钟。每次消毒循环后,将样本在室温下于蒸馏水中储存七天。使用硬度压头在50克力的载荷下持续10秒进行维氏硬度测量。数据进行重复测量双向方差分析测试和Tukey检验。

结果

消毒、牙齿和循环这些变量存在统计学显著差异(牙齿与消毒剂相互作用p<0.05,循环与消毒剂相互作用p<0.05)。一次微波消毒循环后的平均表面硬度低于对照、戊二醛和次氯酸钠。各循环之间的比较显示,微波消毒三个循环后显微硬度显著降低。

结论

得出的结论是,牙齿进行化学消毒时显微硬度没有显著差异,但微波消毒三个循环会导致不同类型人工牙的显微硬度降低。