Suppr超能文献

变压器油作为环境中多氯联苯 (PCBs) 潜在暴露源的评估:伊朗三个中部省份的研究。

Transformer oils as a potential source of environmental exposure to polychlorinated biphenyls (PCBs): an assessment in three central provinces of Iran.

机构信息

Department of Health Sciences, School of Health, Safety and Environment, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Department of Virtual Education, School of Medical Education Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

出版信息

Environ Sci Pollut Res Int. 2017 Aug;24(23):19098-19103. doi: 10.1007/s11356-017-9576-2. Epub 2017 Jun 28.

Abstract

Polychlorinated biphenyl (PCB) contamination of oils from all transformers of the national electrical grid in Tehran, Qom, and Alborz, three central provinces of Iran, was assessed. The concentration of PCBs in transformer oils was determined by gas chromatography. At the national level, the proportions of transformers with oil PCB contents of <5, 5-49, 50-499, 500-4999, and >5000 ppm were determined to be 85.7, 12.4, 1.6, 0.1, and 0.1%, respectively. About 0.5% of transformer oils (66,000 kg out of 13,342,000 kg) exhibited PCB levels higher than 50 ppm that based on the Stockholm Convention should be phased out before 2025. The contaminated oils contained 91.4% of detected PCBs (132 kg PCBs out of 144 kg PCBs) and were located in 1.9% of transformers (27 transformers out of 1449 transformers). Statistical analysis indicated that the year of manufacture and manufacturing company provided significant effects on PCB contamination (p value <0.001). PCB contamination of transformer oils in Tehran was higher than that of the other provinces that could be mainly caused by the older average year of manufacture. PCB levels higher than 499 ppm were also observed only in Tehran. This study provided valuable information for future studies on identification of PCB-contaminated transformers as well as planning and design of waste management facilities for PCB-contaminated oils at the national level.

摘要

对伊朗三个中部省份德黑兰、库姆和阿尔博兹的国家电网所有变压器中的多氯联苯 (PCB) 污染情况进行了评估。通过气相色谱法确定了变压器油中的 PCB 浓度。在国家层面,油中 PCB 含量<5、5-49、50-499、500-4999 和>5000ppm 的变压器比例分别为 85.7%、12.4%、1.6%、0.1%和 0.1%。约 0.5%的变压器油(1334.2 万公斤中的 66000 公斤)表现出高于 50ppm 的 PCB 水平,根据《斯德哥尔摩公约》,这些油应在 2025 年前逐步淘汰。受污染的油中含有 91.4%的已检测到的 PCB(132 公斤 PCB 中有 144 公斤 PCB),位于 1.9%的变压器中(1449 台变压器中有 27 台)。统计分析表明,制造年份和制造公司对 PCB 污染有显著影响(p 值<0.001)。德黑兰的变压器油中 PCB 污染高于其他省份,这主要是由于其平均制造年份较老。仅在德黑兰观察到 PCB 含量高于 499ppm 的情况。本研究为未来识别受 PCB 污染的变压器以及在国家层面规划和设计受 PCB 污染油的废物管理设施提供了有价值的信息。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验