Clinic of Pediatrics, Clinical Center, Zorana Djindjica 48 Boulevard, Nis, 18000, Serbia.
Medical Faculty, University of Nis, Nis, Serbia.
Clin Auton Res. 2017 Aug;27(4):273-278. doi: 10.1007/s10286-017-0445-3. Epub 2017 Jun 30.
Over the last decades, time domain heart rate (HR) variability analysis has been explored in different pediatric clinical settings to obtain information on the cardiac autonomic tone. However, the consistency over time of 24 h time domain HRV measurements in children is not well-known.
We investigated the reproducibility of 24 h HRV time-domain indices (1 day apart), from 39 healthy children (9.5 ± 5.3 years, 56.4% girls). The parameters analysed included: standard deviation of all the adjacent NN intervals, standard deviation of the averages of NN intervals (the intervals between normal R-peaks) in all 5-min segments, and square root of the mean of the sum of the squares of the differences between adjacent NN intervals, uncorrected and corrected for HR. Reproducibility between two 24-h ECG recordings was evaluated by intraclass correlation coefficients, standard error of measurement, coefficients of variation and Bland-Altman plots.
For the analyzed time-domain indices, standard deviation of all the adjacent NN intervals corrected for HR showed best reproducibility with the highest intraclass correlation coefficient (0.987), the lowest coefficients of variation (5.5%) and the best level of agreement between two recordings as assessed by Bland-Altman plots.
Our results indicate that the standard deviation of all the adjacent NN intervals corrected for the HR parameter obtained from 24-h ambulatory recordings in children is consistent and reproducible over time, thus allowing reliable identification of cardiac autonomic tone in this age group.
在过去的几十年中,时域心率(HR)变异性分析已在不同的儿科临床环境中进行了探索,以获取有关心脏自主神经张力的信息。但是,儿童 24 小时时域 HRV 测量的时间一致性尚不清楚。
我们研究了 39 名健康儿童(9.5±5.3 岁,56.4%为女孩)的 24 小时 HRV 时域指数(相隔 1 天)的可重复性。分析的参数包括:所有相邻 NN 间隔的标准差,所有 5 分钟段中 NN 间隔平均值(正常 R 波峰之间的间隔)的标准差,以及未校正和校正 HR 的相邻 NN 间隔平方和的平均值的平方根。通过组内相关系数、测量误差的标准误差、变异系数和 Bland-Altman 图评估两次 24 小时 ECG 记录之间的可重复性。
对于分析的时域指数,校正 HR 的所有相邻 NN 间隔的标准差显示出最佳的可重复性,具有最高的组内相关系数(0.987)、最低的变异系数(5.5%)和 Bland-Altman 图评估的两次记录之间的最佳一致性水平。
我们的结果表明,从儿童 24 小时动态记录中获得的校正 HR 参数的所有相邻 NN 间隔的标准差是一致且可重复的,因此可以可靠地识别该年龄组的心脏自主神经张力。