Faculty of Medicine, University Pierre et Marie Curie, Paris, France; Plastic Surgery Department, APHP, Hôpital Tenon, Paris, France; Department of Microsurgery, Faculty of Medicine, School of Surgery of Paris, University Pierre et Marie Curie, Paris, France; Inserm; Institut National de la Sante et de la Recherche Medicale 1148, Laboratory for Vascular Translational Science, University Paris Diderot, University Paris 13, CHU X Bichat, Paris, France.

Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts.

出版信息

J Surg Educ. 2018 Jan-Feb;75(1):182-187. doi: 10.1016/j.jsurg.2017.06.008. Epub 2017 Jul 1.

Abstract

INTRODUCTION

Assessment of a resident's microsurgical competency with the rodent model remains the current gold standard. However, cost and ethical issues related to animal welfare may limit training opportunities. Therefore, synthetic alternatives such as silicone tubes have been developed to provide easy access to training, shorten the learning curve, and have been incorporated into microsurgical courses as a low-fidelity model for basic skills acquisition. This study compares the use of polyvinyl alcohol (PVA) gelatin tubes with silicone for resident microsurgical training.

MATERIAL AND METHODS

Residents were randomized into silicone (S) or PVA (P) groups and underwent the same training. Following basic instruction, microsurgical anastomoses were performed with the rat's aorta or carotid artery or both. Performance was assessed using the Objective Structured Assessment of Technical Skills (OSATS) score and 5 different items to assess the quality of the anastomosis. Posttest questionnaires were also conducted for qualitative assessment of both students' and trainers' experience with silicone and PVA in comparison with rat vessels.

RESULTS

OSATS score in Group P was higher than Group S (18.2 ± 2.6 vs 16.6 ± 2.5, p = 0.015). Results of anastomoses were similarly better in Group P based on OSATS score (19.3 ± 1.2 vs 17.7 ± 0.7, p = 0.027). Subjectively, both students and trainers found that PVA tubes resembled the rat aorta more closely than silicone. The number of rats used was also significantly lower in Group P than Group S (65 vs 75 total, p = 0.023).

CONCLUSION

PVA gelatin tubes may be a viable alternative to silicone for microsurgical training because this synthetic model mirrors better rat vessels and can improve training performance based on objective assessment while using less animals overall.

摘要

引言

使用啮齿动物模型评估住院医师的显微手术能力仍是当前的金标准。然而,与动物福利相关的成本和伦理问题可能会限制培训机会。因此,已开发出诸如硅胶管之类的合成替代品,以提供便捷的培训途径,缩短学习曲线,并已作为获取基本技能的低保真模型纳入显微外科学课程。本研究比较了使用聚乙烯醇(PVA)明胶管和硅胶进行住院医师显微手术培训的效果。

材料与方法

将住院医师随机分为硅胶组(S)或PVA组(P),并接受相同的培训。在基本指导之后,对大鼠的主动脉或颈动脉或两者进行显微手术吻合。使用客观结构化技术技能评估(OSATS)评分和5个不同项目来评估吻合质量,以此评估操作表现。还进行了测试后问卷调查,以定性评估学生和培训人员使用硅胶和PVA与大鼠血管相比的经验。

结果

P组的OSATS评分高于S组(18.2±2.6对16.6±2.5,p = 0.015)。基于OSATS评分,P组的吻合结果同样更好(19.3±1.2对17.7±0.7,p = 0.027)。主观上,学生和培训人员都发现PVA管比硅胶管更接近大鼠主动脉。P组使用的大鼠数量也明显低于S组(总共65只对75只,p = 0.023)。

结论

PVA明胶管可能是用于显微手术培训的硅胶的可行替代品,因为这种合成模型更能反映大鼠血管,并且在总体使用较少动物的情况下,基于客观评估可以提高培训效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验