Cho Yoon Je, Bae Chan Il, Yoon Wan Keun, Chun Young Soo, Rhyu Kee Hyung
Department of Orthopaedic Surgery, Kyung Hee University Hospital, 23 Kyung Hee Dae-ro, Dongdaemoon-ku, Seoul, 02447, South Korea.
Department of Orthopaedic Surgery, Kyung Hee University Hospital at Gangdong, 892 Dongnam-ro, Gangdong-ku, Seoul, 05278, South Korea.
Int Orthop. 2018 Feb;42(2):303-309. doi: 10.1007/s00264-017-3544-9. Epub 2017 Jul 5.
Load transfer to the bone is believed to be more physiological around the short stem in total hip arthroplasty (THA). However, we found unusual bony remodeling around the shortened tapered stem. This study was performed to investigate the extent and frequency of this phenomenon and to find the possible risk factors of it.
Among 121 consecutive THA using the same short stem, 80 THAs were enrolled. Radiographic measurements were made using anteroposterior (AP) radiographs taken immediately and at two years after surgery. The thickness of the lateral cortex at the level of the distal end of the coated surface and at 10, 20, 30, and 40 mm proximal to it were measured.
Significant atrophy was noted in all regions (P < 0.001 each). In 46 cases, this presented as an intra-cortical osteolytic line (IOL). Sixty-one cases showed either an IOL or atrophy >10%. The risk of a mean reduction >20% was related to an increased operating time (odds ratio [OR] = 0.981; 0.966 < 95% confidence interval [CI] < 0.996) and lower body mass index (BMI) (OR = 1.216; 1.043 < 95% CI < 1.417). Periprosthetic fracture through the lateral cortex occurred in one case.
Even with THA using a shortened stem, high incidence of proximal stress shielding was noted in the form of lateral cortical atrophy, especially for the patient with low BMI.
在全髋关节置换术(THA)中,人们认为短柄假体周围的负荷向骨骼的传递更符合生理情况。然而,我们发现缩短的锥形柄周围出现了异常的骨重塑。本研究旨在调查这种现象的程度和发生率,并找出其可能的危险因素。
在连续进行的121例使用同一短柄假体的THA中,纳入了80例。使用术后即刻及术后两年拍摄的前后位(AP)X线片进行影像学测量。测量涂层表面远端水平及其近端10、20、30和40毫米处外侧皮质的厚度。
所有区域均出现明显萎缩(各P<0.001)。46例表现为皮质内溶骨线(IOL)。61例表现为IOL或萎缩> 10%。平均减少> 20%的风险与手术时间延长(优势比[OR]=0.981;0.966<95%置信区间[CI]<0.996)和较低的体重指数(BMI)(OR=1.216;1.043<95%CI<1.417)有关。1例发生了通过外侧皮质的假体周围骨折。
即使在使用缩短柄的THA中,近端应力遮挡的高发生率也以外侧皮质萎缩的形式出现,尤其是对于BMI较低的患者。