Although provisional pacemaker implantation can safely be done in many cases, a rare complication such as knotted electrode has been described, especially when the procedure is performed without fluoroscopy guidance. We describe a case of knot creation in a provisional pacemaker which was successfully retrieved using a snare after cutting the electrode proximally.
尽管在许多情况下可以安全地进行临时起搏器植入,但已经描述了一种罕见的并发症,如电极打结,尤其是在没有荧光透视引导的情况下进行该操作时。我们描述了一例临时起搏器电极打结的病例,在近端切断电极后使用圈套器成功取出。