The aim of the present study was to examine the clinical utility of complex auditory brainstem response (c-ABR) and investigate if c-ABR is helpful in the diagnostic procedure. Thirty-one adult psychiatric patients, thoroughly diagnosed with autism spectrum disorder (ASD) (n=16), ADHD (n=8), or schizophrenia spectrum disorder (SSD) (n=7) and 15 healthy controls (HC), were blindly assessed with SensoDetect BERA. This c-ABR correctly identified psychiatric diagnoses in 4 patients (13%) and provided partially correct diagnoses in 11 more patients. Of the 15 HC, 6 were misclassified as psychiatric patients. The Cohen´s kappa coefficient (κ) was substantial for HC (κ=0.67), fair for SSD (κ=0.37), slight for ADHD (κ=0.09) and without agreement in ASD (κ=-0.03). In conclusion, we found the c-ABR method unhelpful and unreliable as a tool in clinical diagnostics.
本研究旨在探讨复杂听觉脑干反应(c-ABR)的临床应用,并研究其在诊断中的作用。31 名成年精神科患者,包括 16 名自闭症谱系障碍(ASD)患者、8 名注意力缺陷多动障碍(ADHD)患者和 7 名精神分裂症谱系障碍(SSD)患者,以及 15 名健康对照组(HC),均接受了 SensoDetect BERA 的盲法评估。该 c-ABR 正确识别了 4 名患者(13%)的精神科诊断,并对另外 11 名患者提供了部分正确诊断。15 名 HC 中,有 6 名被错误分类为精神科患者。HC 的 Cohen's kappa 系数(κ)为 0.67,SSD 为 0.37,ADHD 为 0.09,而 ASD 则无一致性(κ=-0.03)。总之,我们发现 c-ABR 方法在临床诊断中无用且不可靠。