文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Ultrasonography and dual-energy computed tomography provide different quantification of urate burden in gout: results from a cross-sectional study.

作者信息

Pascart Tristan, Grandjean Agathe, Norberciak Laurène, Ducoulombier Vincent, Motte Marguerite, Luraschi Hélène, Vandecandelaere Marie, Godart Catherine, Houvenagel Eric, Namane Nasser, Budzik Jean-François

机构信息

Department of Rheumatology, Lille Catholic Hospitals, University of Lille, F-59160, Lomme, France.

EA 4490, PMOI, Physiopathologie des Maladies Osseuses Inflammatoires, University of Lille, F-59000, Lille, France.

出版信息

Arthritis Res Ther. 2017 Jul 21;19(1):171. doi: 10.1186/s13075-017-1381-2.


DOI:10.1186/s13075-017-1381-2
PMID:28732526
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC5521183/
Abstract

BACKGROUND: Ultrasonography (US) and dual-energy computed tomography (DECT) can assess urate burden in gout. The objective of this study was to compare the quantification of urate deposition provided by US to the one provided by DECT. METHODS: Patients with a diagnosis of gout were prospectively recruited to undergo quantification of urate deposition using US and DECT. US examination for tophi and the double contour (DC) sign was performed on the knees and feet and corresponding DECT scans provided volumes of tophi and of overall urate deposition. The primary endpoint was the intra-class correlation coefficient (ICC) of the volume of the index tophus measured by US and DECT and its 95% confidence interval (CI 95%). RESULTS: Of the 64 patients included, 34 presented with at least one tophus on US. DECT inter-reader agreement for urate deposition was perfect with an ICC of 1 (1-1) and good for the measurement of the index tophus with an ICC of 0.69 (0.47-0.83). The ICC for the measurement of the index tophus between the two techniques was poor with a value of 0.45 (0.1-0.71). The average ratio between the index tophi volume as assessed by DECT and US was 0.65. The number of DC-positive joints did not correlate with DECT volume of overall deposits (Spearman correlation coefficient of 0.23). CONCLUSIONS: DECT measurements of tophi give smaller volumes to the same tophi measured with US, and US signs of urate deposition in joints do not correlate with overall DECT volumes of extra-articular deposition.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b10c/5521183/2d1e57ce7f64/13075_2017_1381_Fig2_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b10c/5521183/c7d1204a3f98/13075_2017_1381_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b10c/5521183/2d1e57ce7f64/13075_2017_1381_Fig2_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b10c/5521183/c7d1204a3f98/13075_2017_1381_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b10c/5521183/2d1e57ce7f64/13075_2017_1381_Fig2_HTML.jpg

相似文献

[1]
Ultrasonography and dual-energy computed tomography provide different quantification of urate burden in gout: results from a cross-sectional study.

Arthritis Res Ther. 2017-7-21

[2]
The lack of association between the burden of monosodium urate crystals assessed with dual-energy computed tomography or ultrasonography with cardiovascular risk in the commonly high-risk gout patient.

Arthritis Res Ther. 2018-5-29

[3]
Assessment of tophus size: a comparison between physical measurement methods and dual-energy computed tomography scanning.

J Clin Rheumatol. 2012-1

[4]
Comparison of dual-energy CT, ultrasound and surface measurement for assessing tophus dissolution during rapid urate debulking.

Clin Rheumatol. 2017-6-16

[5]
Dual energy computed tomography in tophaceous gout.

Ann Rheum Dis. 2009-10

[6]
Monosodium urate burden assessed with dual-energy computed tomography predicts the risk of flares in gout: a 12-month observational study : MSU burden and risk of gout flare.

Arthritis Res Ther. 2018-9-17

[7]
Development of a Dual-Energy Computed Tomography Scoring System for Measurement of Urate Deposition in Gout.

Arthritis Care Res (Hoboken). 2016-6

[8]
Lack of change in urate deposition by dual-energy computed tomography among clinically stable patients with long-standing tophaceous gout: a prospective longitudinal study.

Arthritis Res Ther. 2013-10-23

[9]
Relationship between urate within tophus and bone erosion according to the anatomic location of urate deposition in gout: A quantitative analysis using dual-energy CT volume measurements.

Medicine (Baltimore). 2019-12

[10]
Diagnostic value of ultrasound versus dual-energy computed tomography in patients with different stages of acute gouty arthritis.

Clin Rheumatol. 2020-5

引用本文的文献

[1]
Advanced imaging techniques in crystal arthritis.

Ther Adv Musculoskelet Dis. 2025-2-4

[2]
Correlations of characteristics with tissue involvement in knee gouty arthritis: Magnetic resonance imaging analysis.

Heliyon. 2024-5-23

[3]
Factors influencing the kinetics of MSU crystal depletion measured with dual-energy CT in patients with gout.

RMD Open. 2023-11

[4]
Burden and distribution of monosodium urate deposition in patients with hyperuricemia and gout: a cross-sectional Chinese population-based dual-energy CT study.

Quant Imaging Med Surg. 2023-7-1

[5]
Associations of Changes in Knee Hyaline Cartilage Composition Measured With Dual-Energy Computed Tomography in Gout, Aging and Osteoarthritis.

Cartilage. 2024-9

[6]
The Role of Advanced Imaging in Gout Management.

Front Immunol. 2021

[7]
Optimization of dual energy computed tomography post-processing to reduce lower limb artifacts in gout.

Quant Imaging Med Surg. 2022-1

[8]
Sonographic estimation of monosodium urate burden predicts the fulfillment of the 2016 remission criteria for gout: a 12-month study.

Arthritis Res Ther. 2021-7-9

[9]
Entheseal involvement of the lower extremities in gout: an ultrasonographic descriptive observational study.

Clin Rheumatol. 2021-11

[10]
Ultrasonography and dual-energy computed tomography: impact for the detection of gouty deposits.

Ultrasonography. 2021-4

本文引用的文献

[1]
Advanced imaging assessment of gout: comparison of dual-energy CT and MRI with anatomical pathology.

Ann Rheum Dis. 2018-4

[2]
Serum Uric Acid and the Risk of Incident and Recurrent Gout: A Systematic Review.

J Rheumatol. 2017-3

[3]
Treat-to-target (T2T) recommendations for gout.

Ann Rheum Dis. 2016-9-22

[4]
Urate crystal deposition and bone erosion in gout: 'inside-out' or 'outside-in'? A dual-energy computed tomography study.

Arthritis Res Ther. 2016-9-15

[5]
Temporal evolution of urate crystal deposition over articular cartilage after successful urate-lowering therapy in patients with gout: An ultrasonographic perspective.

Mod Rheumatol. 2016-8-5

[6]
2016 updated EULAR evidence-based recommendations for the management of gout.

Ann Rheum Dis. 2016-7-25

[7]
Gout.

Lancet. 2016-10-22

[8]
Gouty arthritis: the diagnostic and therapeutic impact of dual-energy CT.

Eur Radiol. 2016-11

[9]
Imaging as a potential outcome measure in gout studies: A systematic literature review.

Semin Arthritis Rheum. 2016-4

[10]
Tophus resolution with pegloticase: a prospective dual-energy CT study.

RMD Open. 2015-6-17

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索