Alqadami Ayoub Abdullah, Naushad Mu, Abulhassan Abdalla Mohammad, Khan Mohammad Rizwan, Alothman Zeid Abdullah, Wabaidur Saikh Mohammad, Ghfar Ayman Abdel
Department of Chemistry, College of Science, Bld#5, King Saud University, Riyadh, Saudi Arabia.
IET Nanobiotechnol. 2017 Aug;11(5):597-603. doi: 10.1049/iet-nbt.2016.0212.
In this study, the determination of noxious heavy metals, cadmium (Cd), bismuth (Bi), mercury (Hg), titanium (Ti), lead (Pb) and metalloid arsenic (As) in skin-whitening cosmetics were examined using microwave digestion and inductively coupled plasma atomic emission spectrometry method. A complete digestion of cosmetics samples was achieved using a mixture of hydrofluoric acid/hydrogen peroxide/nitric acid. The quantification of the target compounds was done by standard addition method. The excellent quality parameters for instance, detection limits, As (4.6 ppb), Bi (7.9 ppb), Cd (0.45 ppb), Hg (3.3 ppb), Pb (3.8 ppb), Ti (4.3 ppb), linearity ( > 0.999) and run-to-run and day-to-day precisions with relative standard deviations <3% were obtained. The recovery rates for standard reference materials were found between 90 and 105%. The average concentration of heavy metals in cosmetics samples were in the range of 1.0-12.3 (μg g, As), 33-7097 (μg g, Bi), 0.20-0.6 (μg g, Cd), 0.70-2700 (μg g, Hg), 1.20-143 (μg g, Pb) and 2.0-1650 (μg g, Ti).
在本研究中,采用微波消解和电感耦合等离子体原子发射光谱法对美白化妆品中有害重金属镉(Cd)、铋(Bi)、汞(Hg)、钛(Ti)、铅(Pb)和类金属砷(As)进行了测定。使用氢氟酸/过氧化氢/硝酸的混合物实现了化妆品样品的完全消解。通过标准加入法对目标化合物进行定量。获得了优异的质量参数,例如,检测限分别为砷(4.6 ppb)、铋(7.9 ppb)、镉(0.45 ppb)、汞(3.3 ppb)、铅(3.8 ppb)、钛(4.3 ppb),线性度(>0.999)以及批内和批间精密度,相对标准偏差<3%。标准参考物质的回收率在90%至105%之间。化妆品样品中重金属的平均浓度范围为1.0 - 12.3(μg g,砷)、33 - 7097(μg g,铋)、0.20 - 0.6(μg g,镉)、0.70 - 2700(μg g,汞)、1.20 - 143(μg g,铅)和2.0 - 1650(μg g,钛)。