Department of Biological and Medical Psychology, University of Bergen, Bergen, Norway.
Sci Rep. 2017 Jul 27;7(1):6748. doi: 10.1038/s41598-017-06006-4.
Enzyme-linked immunosorbent assay (ELISA) kits are widely used to quantify corticosterone levels for the assessment of stress in laboratory animals. The aim of this experiment was simply to evaluate if four different and widely used commercial ELISA assays would yield the same or similar values of corticosterone in serum samples taken from laboratory rats after the mild stress of being held for sampling blood from the saphenous vein. Trunk blood was sampled from 32 male Wistar rats 30 minutes after this mild stress exposure and analysed with each of four commercial ELISA kits. Both the Arbor Assays and the DRG-4164 kits were significantly higher than the DRG-5186 and the Enzo kits. There were no significant differences between the DRG-5186 and Enzo kits. Overall the correlations between kits were high. In conclusion, the commercial ELISA kits tested in the present experiment yielded different values of total corticosterone in the same serum samples. The precision in determining true values of the corticosterone level is low for these commercial ELISA kits, although they may be used to determine relative differences within studies.
酶联免疫吸附测定(ELISA)试剂盒广泛用于定量检测皮质酮水平,以评估实验室动物的应激状态。本实验的目的只是评估在从跗静脉采集血液样本轻度应激后,来自实验室大鼠的血清样本中,四种广泛使用的商业 ELISA 试剂盒是否会产生相同或相似的皮质酮值。在轻度应激暴露 30 分钟后,从 32 只雄性 Wistar 大鼠中采集了 trunk 血,并使用四种商业 ELISA 试剂盒中的每一种进行了分析。 Arbor 试剂盒和 DRG-4164 试剂盒均显著高于 DRG-5186 和 Enzo 试剂盒。DRG-5186 和 Enzo 试剂盒之间没有显著差异。总体而言,试剂盒之间的相关性很高。总之,本实验中测试的商业 ELISA 试剂盒在相同的血清样本中产生了不同的总皮质酮值。这些商业 ELISA 试剂盒在确定皮质酮水平的真实值方面精度较低,但它们可用于确定研究中的相对差异。