新型凝胶支架植入后对滤过泡形态及眼压降低和青光眼药物使用减少的评估。

Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent.

作者信息

Fea Antonio Maria, Spinetta Roberta, Cannizzo Paola Maria Loredana, Consolandi Giulia, Lavia Carlo, Aragno Vittoria, Germinetti Francesco, Rolle Teresa

机构信息

Clinica Oculistica, Dipartimento di Scienze Chirugiche, Universita' di Torino, Via Juvarra 19, 10100 Torino, Italy.

出版信息

J Ophthalmol. 2017;2017:9364910. doi: 10.1155/2017/9364910. Epub 2017 Jun 20.

Abstract

OBJECTIVE

To evaluate the efficacy and safety of the Xen Gel Stent and provide a macro- and microscopic analyses of bleb morphology.

METHODS

A prospective 12-month study on patients with primary open-angle glaucoma. Patients underwent implantation of the XEN Gel Stent (Allergan INC, Dublin, Ireland) either alone or combined with a cataract surgery. Biomicroscopy, in vivo confocal microscopy (IVCM), and anterior segment-optical coherence tomography (AS-OCT) were used to assess bleb morphology. Safety parameters were adverse events, best corrected visual acuity, visual field, and corneal endothelial cell loss. A postoperative IOP ≤ 18 mmHg without or on medications was respectively defined as complete and qualified success while an IOP ≥ 18 mmHg was defined as failure.

RESULTS

Twelve eyes of 11 patients were evaluated. At one year, 5 out of 10 patients available achieved a complete success while five were qualified success. AS-OCT showed that bleb wall reflectivity was significantly higher in the failure group; IVCM revealed that stromal density was significantly lower in the success group. No safety issues were recorded.

CONCLUSION

Implantation of the XEN Gel Stent appears to be a safe and effective procedure. AS-OCT and IVCM may be helpful in bleb assessment.

摘要

目的

评估Xen凝胶支架的疗效和安全性,并对滤过泡形态进行宏观和微观分析。

方法

对原发性开角型青光眼患者进行为期12个月的前瞻性研究。患者单独或联合白内障手术植入XEN凝胶支架(爱尔兰都柏林的艾尔建公司)。使用生物显微镜检查、体内共焦显微镜检查(IVCM)和眼前节光学相干断层扫描(AS-OCT)评估滤过泡形态。安全参数包括不良事件、最佳矫正视力、视野和角膜内皮细胞损失。术后眼压≤18 mmHg且无需用药或用药后达到此眼压分别定义为完全成功和合格成功,眼压≥18 mmHg定义为失败。

结果

评估了11例患者的12只眼。一年时,10例可评估患者中有5例完全成功,5例合格成功。AS-OCT显示失败组滤过泡壁反射率显著更高;IVCM显示成功组基质密度显著更低。未记录到安全问题。

结论

植入XEN凝胶支架似乎是一种安全有效的手术。AS-OCT和IVCM可能有助于滤过泡评估。