Keeshen Thomas, Case J Brad, Wellehan James F, Dujowich Mauricio
Dr. Thomas P. Keeshen, Animal Speciality Group, 4641 Colorado Blvd, Los Angeles, CA 90039, United States, E-mail:
Vet Comp Orthop Traumatol. 2017 Sep 12;30(5):346-350. doi: 10.3415/VCOT-17-02-0031. Epub 2018 Aug 1.
To evaluate the use of sonication to improve recovery of bacteria from metal discs infected with bacteria commonly associated with implant infections in veterinary medicine.
In vitro study in which sterile titanium (Ti6Al4V) and stainless steel (AIS1316-L) discs were incubated with either Staphylococcus pseudintermedius or Pseudomonas aeruginosa for 24 hours. The following three groups were compared: 1) the sonication group involved immersing the discs in sterile saline and sonicating for five minutes; 2) the sham group was considered a negative control in which the discs were immersed in saline for five minutes without sonication; and 3) the swab group involved systematically swabbing the implant with a sterile culturette. All samples were plated on blood agar and incubated for 24 hours. Colonies were then counted and compared.
For both species of bacteria, there was a significant increase in bacterial colonies isolated using sonication compared to the other two study groups (p = 0.0001). No differences in bacterial growth were found between the two types of metal implants. There was a significant increase in bacterial colony counts for S. pseudintermedius when comparing the swab group versus the sham group, but this was not significant for P. aeruginosa.
Sonication significantly improves recovery of bacteria commonly associated with veterinary implant-associated surgical site infections compared to swabbing of implants in vitro. A prospective clinical evaluation is indicated to determine the in vivo efficacy of sonication in veterinary patients.
评估超声处理对从感染了兽医学中常见的与植入物感染相关细菌的金属圆盘上回收细菌的效果。
进行体外研究,将无菌钛(Ti6Al4V)和不锈钢(AIS1316-L)圆盘与中间型葡萄球菌或铜绿假单胞菌一起孵育24小时。比较以下三组:1)超声处理组,将圆盘浸入无菌盐水中并超声处理5分钟;2)假手术组作为阴性对照,将圆盘浸入盐水中5分钟但不进行超声处理;3)拭子组,用无菌培养管系统地擦拭植入物。所有样本均接种在血琼脂上并孵育24小时。然后对菌落进行计数并比较。
对于这两种细菌,与其他两个研究组相比,使用超声处理分离出的细菌菌落显著增加(p = 0.0001)。两种类型的金属植入物之间未发现细菌生长差异。比较拭子组和假手术组时,中间型葡萄球菌的细菌菌落计数显著增加,但铜绿假单胞菌的情况不显著。
与体外擦拭植入物相比,超声处理显著提高了与兽用植入物相关手术部位感染常见细菌的回收效率。需要进行前瞻性临床评估以确定超声处理在兽医患者体内的疗效。