Jiang Lei, Lu Xu, Hua Bin, Gao Jiayin, Zheng Dandan, Zhou Yiming
J Comput Assist Tomogr. 2018 Jan/Feb;42(1):6-11. doi: 10.1097/RCT.0000000000000661.
The aim of this study was to investigate the diagnostic performance of the perfusion-related parameters of intravoxel incoherent motion (IVIM) imaging for breast lesions, compared with dynamic contrast-enhanced magnetic resonance imaging (DCE MRI).
Fifty-nine patients with both IVIM imaging and subsequent DCE MRI were enrolled. Perfusion-related parameters of IVIM imaging (perfusion fraction, f; pseudo-diffusion coefficient, D*), as well as model-based and model-free parameters of DCE MRI, were measured. Receiver operating characteristic curve analysis and correlations between the IVIM and DCE MRI parameters were performed.
Thirty-one malignant and 35 benign lesions were pathologically proved. The area under the receiver operating characteristic curves (AUC) of D* plus f (AUCf+D*) was 0.834. The combined AUC of all model-based DCE MRI parameters (AUCmodel-based) was 0.904. The combined AUC of all model-free DCE MRI parameters (AUCmodel-free) was 0.876. AUCf+D* had no significant difference with either AUCmodel-based or AUCmodel-free. No significant correlation was found between f or D* and DCE-derived parameters.
Intravoxel incoherent motion imaging has the same value in differentiating malignant and benign breast lesions, compared with DCE MRI, in terms of perfusion-related parameters.
本研究旨在对比体素内不相干运动(IVIM)成像与动态对比增强磁共振成像(DCE MRI),探讨IVIM成像灌注相关参数对乳腺病变的诊断效能。
纳入59例同时接受IVIM成像及后续DCE MRI检查的患者。测量IVIM成像的灌注相关参数(灌注分数,f;伪扩散系数,D*)以及DCE MRI基于模型和不基于模型的参数。进行受试者操作特征曲线分析以及IVIM与DCE MRI参数之间的相关性分析。
31个恶性病变和35个良性病变经病理证实。D加f(AUCf+D)的受试者操作特征曲线下面积为0.834。所有基于模型的DCE MRI参数的联合AUC(AUCmodel-based)为0.904。所有不基于模型的DCE MRI参数的联合AUC(AUCmodel-free)为0.876。AUCf+D与AUCmodel-based或AUCmodel-free均无显著差异。f或D与DCE衍生参数之间未发现显著相关性。
就灌注相关参数而言,与DCE MRI相比,体素内不相干运动成像在鉴别乳腺良恶性病变方面具有相同价值。