Suppr超能文献

微切口双轴白内障手术联合植入Incise人工晶状体后的临床结果。

Clinical results after microincision biaxial cataract surgery and implantation of an Incise intraocular lens.

作者信息

Lubiński Wojciech, Kirkiewicz Marta, Podborączyńska-Jodko Karolina

机构信息

Clinic of Ophthalmology, Pomeranian Medical University, al. Powstańców Wielkopolskich 72, 70-111, Szczecin, Poland.

出版信息

Int Ophthalmol. 2018 Oct;38(5):1977-1983. doi: 10.1007/s10792-017-0686-0. Epub 2017 Aug 12.

Abstract

PURPOSE

To evaluate clinical outcomes after uncomplicated microincision biaxial cataract surgery and implantation of Incise intraocular lens (IOL).

METHODS

This study included 47 eyes of 29 patients (mean age 62.2 ± 8.6 years), who underwent 1.4-mm biaxial cataract surgery with implantation of the Incise IOL (Bausch and Lomb). At third month, surgically induced astigmatism (SIA) was calculated. Three, 6 and 12 months postoperatively, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA) LogMAR ETDRS, spherical equivalent refraction (SER), photopic distance corrected contrast sensitivity (CS) with and without glare (85 cd/m) (CSV-1000) were assessed. One year after surgery, late complications were assessed and subjects were questioned for subjective symptoms.

RESULTS

Mean of SIA was equal 0.29 ± 0.16 D. Three months postoperatively: mean UDVA improved from 0.83 to 0.04 (p < 0.001), CDVA from 0.58 to -0.05 (p < 0.001) and CNVA from 0.58 to -0.02 (p < 0.001) and all were stable during 1-year follow-up. Three months postoperatively, the mean SER was equal 0.07 ± 0.61 D and was within ±0.5 D in 79%, and within 1 D in 88% of eyes. During follow-up period, corrected CS with and without glare for distance was found to be within normal limits. The only late complication was posterior capsule opacification (PCO). Subjective quality of vision was very high; none of patients complained about glare.

CONCLUSIONS

Biaxial cataract surgery with implantation of the Incise IOL provided excellent clinical outcomes by minimizing SIA, stable refraction and low incidence of PCO.

摘要

目的

评估单纯微切口双轴白内障手术联合植入Incise人工晶状体(IOL)后的临床效果。

方法

本研究纳入29例患者的47只眼(平均年龄62.2±8.6岁),接受了1.4毫米双轴白内障手术并植入Incise IOL(博士伦公司)。在术后第三个月,计算手术源性散光(SIA)。术后3个月、6个月和12个月,评估未矫正远视力(UDVA)、矫正远视力(CDVA)、矫正近视力(CNVA)的LogMAR ETDRS、等效球镜度(SER)、有无眩光(85 cd/m²)时的明视距离矫正对比敏感度(CS)(CSV-1000)。术后一年,评估晚期并发症并询问受试者主观症状。

结果

SIA的平均值为0.29±0.16 D。术后3个月:平均UDVA从0.83提高到0.04(p<0.001),CDVA从0.58提高到-0.05(p<0.001),CNVA从0.58提高到-0.02(p<0.001),且在1年随访期间均保持稳定。术后3个月,平均SER为0.07±0.61 D,79%的眼在±0.5 D范围内,88%的眼在1 D范围内。在随访期间,有眩光和无眩光时的矫正距离CS均在正常范围内。唯一的晚期并发症是后囊膜混浊(PCO)。主观视觉质量非常高;没有患者抱怨眩光。

结论

双轴白内障手术联合植入Incise IOL通过最小化SIA、稳定屈光和低PCO发生率提供了优异的临床效果。