碘克沙醇与碘普罗胺在冠状动脉 CT 血管造影中的比较:管腔显影及对心律的影响——随机对照 IsoCOR 试验。

Iodixanol versus Iopromide at Coronary CT Angiography: Lumen Opacification and Effect on Heart Rhythm-the Randomized IsoCOR Trial.

机构信息

From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schweitzer Ziekenhuis, Dordrecht, the Netherlands; and Departments of Radiology (A.N., H.v.V.) and Cardiology (T.B.), Maasstad Ziekenhuis, Rotterdam, the Netherlands.

出版信息

Radiology. 2018 Jan;286(1):71-80. doi: 10.1148/radiol.2017162779. Epub 2017 Aug 15.

Abstract

Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. RSNA, 2017 Online supplemental material is available for this article.

摘要

目的 当使用当代心脏 CT 方案以相同的碘输送率注射时,证明等渗和低渗对比剂可实现相同的冠状动脉管腔显影,并研究等渗对比剂的心血管效应和获得的图像质量。

材料与方法 本 Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography,或 IsoCOR 试验获得机构审查委员会批准和书面知情同意。2015 年 11 月至 2016 年 8 月,前瞻性随机分配 306 例(167[55%]例女性)至少 18 岁(体重范围 50-125 kg)的患者,分别接受等渗碘克沙醇 270 或低渗碘普罗胺 300 造影剂。使用 Student t 检验比较所有冠状动脉节段的腔内显影和图像质量,并进行比较。还监测心率、心律失常、患者不适和不良事件。

结果 碘克沙醇 270 和碘普罗胺 300 造影剂组的平均测量冠状动脉衰减值±标准差具有可比性(分别为 469 HU ± 167 对 447 HU ± 166[P =.241];95%置信区间:-15.1,60.0),包括亚组分析。调整碘浓度较低后,碘克沙醇 270 推注量大于碘普罗胺 300(分别为 76.8 mL ± 11.6 对 69.7 mL ± 10.8;P <.001)。更高的注射速率与更高的压力相关(分别为 777 kPa ± 308 对 630 kPa ± 252;P <.001)。虽然碘克沙醇 270 组患者感觉热不适的程度较低(分别为 72%对 86%;P <.001),但心率或节律无差异。

结论 如果以可比的碘输送率注射,等渗造影剂碘克沙醇 270 与低渗造影剂碘普罗胺 300 相比,在评估冠状动脉显影方面没有差异。碘克沙醇 270 引起的热不适较少,但与碘普罗胺 300 相比,对心率没有不同影响。RSNA,2017 年 在线补充材料可用于本文。