Schlager Daniel, Maas Moritz, Hein Simon, Adams Fabian, Schoenthaler Martin, Spittau Bjoern, Wetterauer Ulrich, Miernik Arkadiusz
Department of Urology, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Urol Int. 2017;99(4):467-475. doi: 10.1159/000478790. Epub 2017 Aug 17.
Surgical vasectomy remains the gold standard for fertility control in men. Endoluminal occlusion of the seminal ducts, thus avoiding an external incision, may become an appealing alternative to this approach. As our group has shown, nontraumatic endoscopic inspection of the seminal ducts is feasible in the human cadaver. We investigated the feasibility and reliability of occlusion using several commercially available medical sealing agents in the porcine vas deferens (VD).
Tests were conducted using 25 porcine spermatic ducts (10 cm length) ex vivo. The explanted specimens were fixed and cannulated using the Seldinger technique. We administered 5 different agents (n-butyle-2-cyanoacrylate, n-butyle-2-cyanoacrylate in combination with a platinum vascular coil, Tissucol Duo S®, Gelita Spon® and AFP Plug®) endoluminally. Tightness was evaluated after 5, 15, 60, 360, 720, and 1,440 min for each of the five grades, respectively, using a solution of methylene blue and saline injected under controlled pressure of 300 mm Hg followed by histological examination.
All agents were administered into the porcine seminal ducts (4 out of 5 via a ureteric catheter). Gelita Spon® and Tissucol Duo S® did not occlude the lumen sufficiently, whereas n-butyle-2-cyanoacrylate, n-butyle-2-cyanoacrylate in combination with coil, Tissucol Duo and AFP Plug® performed satisfactorily. In particular, cyanoacrylate combined with a coil was able to close the seminal duct tightly and for a long time. Histological findings confirmed this sealant's gapless adhesion. AFP Plug® application revealed similarly good results. However, its form needs to be optimized to ensure its suitability for endoscopic use.
Various developments regarding minimally invasive fertility control methods have been underway for decades. Further miniaturization of endoscopy and novel materials may pave the way for endoscopic fertility control in males in the future. We demonstrated the potential of commercially available medical sealing agents to reliably occlude the porcine VD.
手术输精管结扎术仍是男性生育控制的金标准。精道腔内闭塞,从而避免外部切口,可能成为这种方法的一种有吸引力的替代方案。正如我们团队所表明的,在人体尸体中对精道进行无创内镜检查是可行的。我们研究了使用几种市售医用密封剂在猪输精管(VD)中进行闭塞的可行性和可靠性。
使用25条离体猪精索管(长度为10厘米)进行试验。将取出的标本固定并采用Seldinger技术插管。我们经腔内给予5种不同的试剂(正丁基-2-氰基丙烯酸酯、正丁基-2-氰基丙烯酸酯与铂血管线圈联合使用、Tissucol Duo S®、Gelita Spon®和AFP Plug®)。分别在5、15、60、360、720和1440分钟后,针对五个等级中的每一个等级,使用在300毫米汞柱控制压力下注入的亚甲蓝和盐水溶液评估密封性,随后进行组织学检查。
所有试剂均注入猪精道(5种中有4种通过输尿管导管)。Gelita Spon®和Tissucol Duo S®未能充分闭塞管腔,而正丁基-2-氰基丙烯酸酯、正丁基-2-氰基丙烯酸酯与线圈联合使用、Tissucol Duo和AFP Plug®表现令人满意。特别是,氰基丙烯酸酯与线圈联合使用能够长时间紧密闭合精道。组织学结果证实了这种密封剂的无缝隙粘附。AFP Plug®的应用显示出类似的良好结果。然而,其形状需要优化以确保其适用于内镜使用。
关于微创生育控制方法的各种进展已经进行了数十年。内镜的进一步小型化和新型材料可能为未来男性内镜生育控制铺平道路。我们证明了市售医用密封剂可靠闭塞猪输精管的潜力。