Suppr超能文献

使用安装在四肢的惯性测量单元测量非跛行马小跑时步态模式变量的重复性。

Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.

作者信息

Cruz Antonio M, Maninchedda Ugo E, Burger Dominik, Wanda Sabine, Vidondo Beatriz

出版信息

Am J Vet Res. 2017 Sep;78(9):1011-1018. doi: 10.2460/ajvr.78.9.1011.

Abstract

OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients < 10), and the repeatability coefficients were consistent among the 3 weeks of data collection. Some spatial variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.

摘要

目的 确定在跑步机运动的受控条件下,使用安装在四肢的惯性测量单元(IMU)测量非跛行马匹小跑时步态变量的可重复性。

动物 10 匹马。

程序 将六个 IMU 绑在每匹马的掌骨、跖骨和胫骨远端区域。在每匹马在跑步机上小跑时,以标准化方式收集数据(在 3 周期间,每周 3 天,每天 3 次测量)。每次测量至少包括 20 步,从中选择至少 10 步进行分析。空间和时间变量由 IMU 得出。在每周对每个步态分析变量计算基于受试者内标准差的可重复性系数。

结果 大多数时间和空间变量具有高可重复性(可重复性系数<10),并且在 3 周的数据收集期间可重复性系数是一致的。一些空间变量,特别是对称变量(由其他变量计算得出),仅在最后一周具有稍高的可重复性系数(即较低的可重复性)。

结论及临床意义 除了一些可能反映运动过程中个体差异的对称变量外,安装在四肢的 IMU 为在跑步机运动的受控条件下小跑的非跛行马匹提供了具有高可重复性的数据。对于每个装有仪器的肢体节段,在两个相邻节段之间的空间关系(关节角度)和所有节段之间的时间关系(肢体相位)方面实现了可重复性。安装在四肢的 IMU 有可能成为马匹步态分析的一种方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验