Suppr超能文献

一种用于确定潜血斑法医鲁米诺检验代表性检测限的定量方法。

A quantitative method for determining a representative detection limit of the forensic luminol test for latent bloodstains.

作者信息

Cassidy Brianna M, Lu Zhenyu, Martin Jennifer P, Tazik Shawna K, Kellogg Katie W, DeJong Stephanie A, Belliveau Elle O, Kilgore Katherine E, Ervin Samantha M, Meece-Rayle Mackenzie, Abraham Alyssa M, Myrick Michael L, Morgan Stephen L

机构信息

Department of Chemistry and Biochemistry, University of South Carolina, 631 Sumter Street, Columbia, SC 29208, USA.

出版信息

Forensic Sci Int. 2017 Sep;278:396-403. doi: 10.1016/j.forsciint.2017.06.031. Epub 2017 Jul 5.

Abstract

The luminol test has been used for over 60 years by forensic investigators for presumptive identification of blood and visualization of blood splatter patterns. Multiple studies have estimated the limit of detection (LD) for bloodstains when luminol is employed, with results ranging from 100× to 5,000,000× dilute. However, these studies typically have not identified and controlled important experimental variables which may affect the luminol LD for bloodstains. Without control of experimental parameters in the laboratory, variables which affect the potential of presumptive bloodstain test methods remain largely unknown, and comparisons required to establish new, more powerful detection methods are simply impossible. We have developed a quantitative method to determine the relationship between the amount of blood present and its reaction with luminol by measuring, under controlled conditions, the resulting chemiluminescent intensity with a video camera, combined with processing of the digital intensity data. The method resulted in an estimated LD for bloodstains on cotton fabric at ∼200,000× diluted blood with a specific luminol formulation. Although luminol is the focus of this study, the experimental protocol used could be modified to study effects of variables using other blood detection reagents.

摘要

鲁米诺测试已被法医调查人员使用超过60年,用于血液的初步鉴定和血迹喷溅模式的可视化。多项研究估计了使用鲁米诺时血迹的检测限(LD),结果从100倍稀释到500万倍稀释不等。然而,这些研究通常没有识别和控制可能影响鲁米诺对血迹检测限的重要实验变量。在实验室中如果不控制实验参数,影响血迹初步检测方法潜力的变量在很大程度上仍然未知,而建立新的、更强大的检测方法所需的比较根本无法进行。我们开发了一种定量方法,通过在受控条件下用摄像机测量产生的化学发光强度,并结合数字强度数据处理,来确定存在的血液量与其与鲁米诺反应之间的关系。该方法得出,对于棉织物上的血迹,使用特定鲁米诺配方时,估计检测限约为20万倍稀释血液。尽管鲁米诺是本研究的重点,但所使用的实验方案可以修改,以使用其他血液检测试剂研究变量的影响。