University of Groningen, University Medical Center Groningen, Center for Medical Imaging North-East Netherlands (CMI-NEN), Groningen, The Netherlands.
Erasmus MC-University Medical Centre, Department of Public Health, Rotterdam, The Netherlands.
Acad Radiol. 2018 Jan;25(1):118-128. doi: 10.1016/j.acra.2017.07.010. Epub 2017 Aug 23.
To describe the rationale, design, and technical background of coronary artery calcium (CAC) imaging in the large-scale population-based cardiovascular disease screening trial (Risk Or Benefit IN Screening for CArdiovascular Diseases [ROBINSCA]).
First, literature search was performed to review the logistics, setup, and settings of previously performed CAC imaging studies, and current clinical CAC imaging protocols of participating centers in the ROBINSCA trial were evaluated. A second literature search was performed to evaluate the impact of computed tomography parameter settings on CAC score.
Based on literature reviews and experts opinion an imaging protocol accompanied by data management protocol was created for ROBINSCA. The imaging protocol should consist of a fixed tube voltage, individually tailored tube current setting, mid-diastolic electrocardiography-triggering, fixed field-of-view, fixed reconstruction kernel, fixed slice thickness, overlapping reconstruction and without iterative reconstruction. The analysis of scans is performed with one type and version of CAC scoring software, by two dedicated and experienced researchers. The data management protocol describes the organization of data handling between the coordinating center, participating centers, and core analysis center.
In this paper we describe the rationale and technical considerations to be taken in developing CAC imaging protocol, and we present a detailed protocol that can be implemented for CAC screening purposes.
描述大规模基于人群的心血管疾病筛查试验(风险或益处筛查心血管疾病 [ROBINSCA])中冠状动脉钙化 (CAC) 成像的原理、设计和技术背景。
首先,进行文献检索,以回顾先前进行的 CAC 成像研究的物流、设置和环境,并评估参与 ROBINSCA 试验的中心的当前临床 CAC 成像方案。进行了第二次文献检索,以评估计算机断层扫描参数设置对 CAC 评分的影响。
根据文献综述和专家意见,为 ROBINSCA 创建了一个成像方案和数据管理方案。成像方案应由固定的管电压、个性化的管电流设置、舒张中期心电图触发、固定的视野、固定的重建内核、固定的切片厚度、重叠重建和无迭代重建组成。使用一种类型和版本的 CAC 评分软件,由两名专门且经验丰富的研究人员对扫描进行分析。数据管理方案描述了协调中心、参与中心和核心分析中心之间的数据处理组织。
本文描述了开发 CAC 成像方案时需要考虑的原理和技术注意事项,并提出了可用于 CAC 筛查目的的详细方案。