Suppr超能文献

产后剖宫产术中插入CuT380A和Cu375宫内节育器后尾丝的可视性:一项随机对照研究

Visibility of Strings After Postplacental Intracesarean Insertion of CuT380A and Cu375 Intrauterine Contraceptive Device: A Randomized Comparative Study.

作者信息

Agarwal Kavita, Dewan Rupali, Mittal Pratima, Aggarwal Abha

机构信息

Department of Obstetrics and Gynaecology, Safdarjung Hospital, New Delhi, 110029 India.

NIMS, Delhi, India.

出版信息

J Obstet Gynaecol India. 2017 Oct;67(5):324-329. doi: 10.1007/s13224-017-0965-8. Epub 2017 Jan 30.

Abstract

OBJECTIVES

To compare the incidence of visible strings after postplacental intracesarean insertion of Cu375 and CuT380A intrauterine contraceptive devices (IUD).

METHODS

This was a prospective, randomized comparative study. A total of 100 women fulfilling the inclusion and exclusion criteria underwent postplacental intracesarean insertion of either Cu375 IUD or CuT380A IUD. Women were followed up at 1, 6 weeks and 3 months after IUD insertion and were questioned about IUD expulsion or removal at each visit. The cervix was inspected to visualize the IUD strings. Data were analyzed by Chi-square test.

RESULTS

At 6-week follow-up, 97.9% women in group A versus 41.7% women in group B had strings visible at the cervical os and at 3 months 100% women in group A versus only 47.9% women in group B ( < 0.001) had visible strings of IUD.

CONCLUSION

Both Cu375 and CuT380A IUD are safe postpartum method of contraception but Cu375 if used for intracesarean IUD insertion increases the incidence of visible IUD strings. Hence, it avoids radiological investigations and invasive procedures at follow-up visits required to locate the IUD when strings are not visible. CTRI/2015/09/006221.

摘要

目的

比较胎盘娩出后剖宫产术中插入Cu375和CuT380A宫内节育器(IUD)后可见尾丝的发生率。

方法

这是一项前瞻性随机对照研究。共有100名符合纳入和排除标准的女性在胎盘娩出后剖宫产术中插入Cu375 IUD或CuT380A IUD。在IUD插入后1周、6周和3个月对女性进行随访,每次随访时询问IUD排出或取出情况。检查宫颈以观察IUD尾丝。数据采用卡方检验进行分析。

结果

在6周随访时,A组97.9%的女性宫颈口可见尾丝,而B组为41.7%;在3个月时,A组100%的女性IUD尾丝可见,而B组仅为47.9%(P<0.001)。

结论

Cu375和CuT380A IUD都是安全的产后避孕方法,但如果在剖宫产术中使用Cu375 IUD,会增加IUD尾丝可见的发生率。因此,当尾丝不可见时,它避免了随访时为定位IUD所需的放射学检查和侵入性操作。CTRI/2015/09/006221。

相似文献

2
Non-visualisation of strings after postplacental insertion of Copper-T 380A intrauterine device.
J Fam Plann Reprod Health Care. 2017 Jul;43(3):186-194. doi: 10.1136/jfprhc-2015-101200. Epub 2016 May 20.
3
[Posplacenta intrauterine device. Guide wires not visible].
Ginecol Obstet Mex. 2012 Mar;80(3):201-7.
10
Six-week retention after postplacental copper intrauterine device placement.胎盘后置入含铜宫内节育器后的六周留存情况。
Contraception. 2018 Mar;97(3):215-218. doi: 10.1016/j.contraception.2017.10.012. Epub 2017 Nov 8.

本文引用的文献

1
Non-visualisation of strings after postplacental insertion of Copper-T 380A intrauterine device.
J Fam Plann Reprod Health Care. 2017 Jul;43(3):186-194. doi: 10.1136/jfprhc-2015-101200. Epub 2016 May 20.
8
In-office retrieval of intrauterine contraceptive devices with missing strings.门诊取出尾丝缺失的宫内节育器
Contraception. 2011 Feb;83(2):102-6. doi: 10.1016/j.contraception.2010.07.004. Epub 2010 Aug 23.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验