一种磁悬浮与静压稳定的离心式血泵。

A Magnetically Suspended and Hydrostatically Stabilized Centrifugal Blood Pump.

作者信息

Hart Robert M, Filipenco Victor G, Kung Robert T V

机构信息

ABIOMED R&D, Inc., Danvers, Massachusetts, New York, U.S.A.United Technologies, Carrier Corp., Syracuse, New York, U.S.A.

出版信息

Artif Organs. 1996 May;20(5):591-596. doi: 10.1111/j.1525-1594.1996.tb04487.x.

Abstract

A magnetically suspended centrifugal blood pump intended for application as a long-term implantable ventricular assist device has been built and tested. The rotor is freely suspended in the blood by magnetic and hydrostatic restoring forces. This design obviates the need for bearings and shaft seals, and eliminates the problems of reliability and thrombogenicity associated with them. The positional stability and hydrodynamic performance of the pump has been characterized in vitro at flows of up to 10 L/min at physiologic pressures. Radial position control is realized by an analog electronic feedback control system. The pressure distribution in the fluid surrounding the rotor provides dynamic control in the axial direction with no active feedback. Rotor excursion is less than 50 microns (μ) when the housing receives an impulse peaking at an acceleration of 40 g or upon sudden blockage of the flow. In vitro blood measurements indicate an acceptable level of hemolysis compared with that of a standard centrifugal pump.

摘要

一种旨在用作长期可植入心室辅助装置的磁悬浮离心式血泵已制造并经过测试。转子通过磁力和流体静力恢复力自由悬浮在血液中。这种设计无需轴承和轴封,消除了与之相关的可靠性和血栓形成问题。该泵在生理压力下高达10升/分钟的流量下进行了体外特性研究,包括位置稳定性和流体动力学性能。径向位置控制由模拟电子反馈控制系统实现。转子周围流体中的压力分布在无主动反馈的情况下提供轴向动态控制。当泵壳受到峰值加速度为40g的冲击或流量突然阻塞时,转子偏移小于50微米(μm)。体外血液测量表明,与标准离心泵相比,溶血水平可接受。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验