Suppr超能文献

英国生物银行队列中运动及恢复过程中心率动态变化的长期个体内再现性

Long-term intra-individual reproducibility of heart rate dynamics during exercise and recovery in the UK Biobank cohort.

作者信息

Orini Michele, Tinker Andrew, Munroe Patricia B, Lambiase Pier D

机构信息

Institute of Cardiovascular Science, University College London, London, United Kingdom.

Barts Heart Centre, St Bartholomew's Hospital, London, United Kingdom.

出版信息

PLoS One. 2017 Sep 5;12(9):e0183732. doi: 10.1371/journal.pone.0183732. eCollection 2017.

Abstract

BACKGROUND

The heart rate (HR) response to exercise provides useful information about the autonomic function and has prognostic value, but its reproducibility over a long period of time, a critical requirement for using it as a clinical biomarker, is undetermined.

AIM

To determine the intra-individual reproducibility of HR dynamics during sub-maximum exercise and one minute recovery.

METHODS

1187 individuals from the Cardio physical fitness assessment test of the UK Biobank repeated a standard exercise stress test twice (recall time 34.2 ± 2.8 months) and were prospectively studied.

RESULTS

821 individuals complied with inclusion criteria for reproducibility analysis, including peak workload differences between assessments ≤10 W. Intra-individual correlation between HR profile during the first and the second assessment was very high and higher than inter-individual correlation (0.92±0.08 vs 0.87±0.11, p<0.01). Intra-individual correlation of indices describing HR dynamics was: ρ = 0.81 for maximum HR during exercise; ρ = 0.71 for minimum HR during recovery; ρ = 0.70 for HR changes during both exercise and recovery; Intra-individual correlation was higher for these indices of HR dynamics than for resting HR (ρ = 0.64). Bland-Altman plots demonstrated good agreement between HR indices estimated during the first and second assessment. A small but consistent bias was registered for all repeated measurements. The intra-individual consistency of abnormal values was about 60-70%.

CONCLUSIONS

The HR dynamics during exercise and recovery are reproducible over a period of 3 years, with moderate to strong intra-individual reproducibility of abnormal values.

摘要

背景

运动时的心率(HR)反应可为自主神经功能提供有用信息并具有预后价值,但作为临床生物标志物的一项关键要求,即其长期的可重复性尚未确定。

目的

确定次最大运动及一分钟恢复期间HR动态变化的个体内可重复性。

方法

对英国生物银行心血管体能评估测试中的1187名个体进行前瞻性研究,他们重复进行了两次标准运动应激测试(回忆时间为34.2±2.8个月)。

结果

821名个体符合可重复性分析的纳入标准,包括两次评估之间的峰值工作量差异≤10W。第一次和第二次评估期间HR曲线的个体内相关性非常高,且高于个体间相关性(0.92±0.08对0.87±0.11,p<0.01)。描述HR动态变化的指标的个体内相关性为:运动期间最大HR的ρ=0.81;恢复期间最小HR的ρ=0.71;运动和恢复期间HR变化的ρ=0.70;这些HR动态变化指标的个体内相关性高于静息HR的个体内相关性(ρ=0.64)。Bland-Altman图显示第一次和第二次评估期间估计的HR指标之间具有良好的一致性。所有重复测量均记录到一个小但一致的偏差。异常值的个体内一致性约为60-70%。

结论

运动和恢复期间的HR动态变化在3年内具有可重复性,异常值具有中度至高度的个体内可重复性。