Abstract

INTRODUCTION

The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters.

METHODS AND RESULTS

Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak-Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters.

CONCLUSIONS

Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic-environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

摘要

引言

静息心电图是评估心脏电生理最常用的工具。以往的研究基于这些心脏电活动的快照估计了心电图参数的遗传力。在本研究中,我们旨在确定分析动态心电图的心率特异性数据是否能更全面地评估心电图参数的遗传力。

方法与结果

记录了221对双胞胎的动态心电图,并使用多参数心搏分箱方法进行分析。使用结构方程模型计算了QRS波时限、QT间期、T波峰末间期和T波高度的心率依赖性遗传力估计值。QRS波时限很大程度上由环境因素决定,而复极主要由遗传决定。与静息心电图相比,从动态心电图测量时,QT间期和T波高度的遗传力估计值显著更高,且每个参数的遗传力估计值都与心率有关。对复极参数之间相关性的遗传贡献分析表明,不同心率下个体心电图参数的协方差存在重叠,但在每个特定心率下,不同复极参数的遗传决定因素之间的重叠相对较少。

结论

在此,我们首次对动态心电图测量的复极参数的遗传力进行了研究。我们的数据表明,与静息心电图相比,动态心电图可估计出更高的遗传力,并揭示了心电图遗传环境决定因素中的心率依赖性,这在以前是难以处理的。未来的应用包括对遗传性心脏电疾病参与者的心电图进行更深入的剖析。