Abstract

PURPOSE

To provide additional information on normal values of static pupil diameter measurements for binocular infrared pupillometry with PupilX, a commercial pupillometer, and assess the reproducibility of this device's measurements.

METHODS

The pupil diameters from 91 study participants with normal eyes with an average age of 39.7 years (SD 16.4 years) were measured with PupilX under scotopic (0 lx), mesopic (1 lx), and photopic (16 lx) illumination. To assess the repeatability of the device, each measurement was repeated 5 times.

RESULTS

The mean pupil diameters were 6.5 mm (SD 1.3 mm), 5.5 mm (SD 1.2 mm), and 4.03 mm (SD 0.9 mm) under scotopic, mesopic, and photopic illumination. Left and right eyes showed no difference in mean pupil diameters. The mean unsigned anisocoria was 0.26 mm (SD 0.32 mm) under scotopic, 0.26 mm (SD 0.27 mm) under mesopic, and 0.19 mm (SD 0.19 mm) under photopic illumination. The decrease in pupil diameter with age was largest for scotopic (≈0.057 mm/y) and smallest for photopic illumination (≈0.025 mm/y). The repeatability of the pupillometer was better than 0.2 mm.

CONCLUSIONS

This study provides reference values for age- and light-related pupil diameters measured with the PupilX digital pupillometer in normal subjects.

摘要

目的

使用商用瞳孔计PupilX提供双眼红外瞳孔测量法静态瞳孔直径测量正常值的更多信息,并评估该设备测量的可重复性。

方法

使用PupilX在暗视(0勒克斯)、中间视觉(1勒克斯)和明视(16勒克斯)照明条件下测量91名平均年龄为39.7岁(标准差16.4岁)的正常眼研究参与者的瞳孔直径。为评估该设备的可重复性,每次测量重复5次。

结果

在暗视、中间视觉和明视照明条件下,平均瞳孔直径分别为6.5毫米(标准差1.3毫米)、5.5毫米(标准差1.2毫米)和4.03毫米(标准差0.9毫米)。左眼和右眼的平均瞳孔直径无差异。暗视条件下平均无符号瞳孔不等大值为0.26毫米(标准差0.32毫米),中间视觉条件下为0.26毫米(标准差0.27毫米),明视照明条件下为0.19毫米(标准差0.19毫米)。暗视条件下瞳孔直径随年龄的减小最大(约0.057毫米/年),明视照明条件下最小(约0.025毫米/年)。瞳孔计的可重复性优于0.2毫米。

结论

本研究提供了使用PupilX数字瞳孔计在正常受试者中测量的与年龄和光照相关的瞳孔直径的参考值。