Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee; and
Nuclear Physics Enterprises, Marlton, New Jersey.
J Nucl Med. 2018 Jan;59(1):154-160. doi: 10.2967/jnumed.117.196261. Epub 2017 Sep 8.
A compendium of about 100 radiopharmaceuticals, based on the OLINDA/EXM version 2.0 software, is presented. A new generation of voxel-based, realistic human computational phantoms developed by the RADAR committee of the Society of Nuclear Medicine and Molecular Imaging, based on 2007 recommendations of the International Commission on Radiological Protection, was used to develop the dose estimates, and the most recent biokinetic models were used as well. These estimates will be made available in electronic form and can be modified and updated as models are changed and as new radiopharmaceuticals are added.
本文呈现了基于 OLINDA/EXM 版本 2.0 软件的约 100 种放射性药物的概要。新一代基于体素的、真实的人体计算体模是由核医学与分子影像学会的 RADAR 委员会开发的,该体模基于国际放射防护委员会 2007 年的建议,用于开发剂量估算,并且还使用了最新的生物动力学模型。这些估算将以电子形式提供,并可以根据模型的变化和新放射性药物的添加进行修改和更新。