Stabin Michael G
Hanford Mission Integrated Solutions, Richland, WA.
Health Phys. 2023 May 1;124(5):397-406. doi: 10.1097/HP.0000000000001682. Epub 2023 Feb 13.
The OLINDA/EXM version 2.0 personal computer code was created as an upgrade to the widely used OLINDA/EXM 1.0 and 1.1 codes. This paper documents the upgrades that were implemented. New decay data and anthropomorphic and biokinetic models were implemented in the software, and the software alpha and beta tested. Agreement of doses between the OLINDA/EXM codes 1 and 2 was very good. Use of the new anthropomorphic and biokinetic models results in understandable differences between the codes. Previous models were retained in the new code, and those results were identical to those in the previous code. OLINDA/EXM 2.0 represents an upgrade from version 1, with new modeling data recommended by the international community. It standardizes internal dose calculations for dose assessments in clinical trials with radiopharmaceuticals, theoretical calculations for existing pharmaceuticals, teaching, and other purposes.
OLINDA/EXM 2.0个人计算机代码是作为对广泛使用的OLINDA/EXM 1.0和1.1代码的升级而创建的。本文记录了所实施的升级内容。新的衰变数据以及人体模型和生物动力学模型已在软件中实施,并对软件进行了alpha和beta测试。OLINDA/EXM代码1和2之间的剂量一致性非常好。新的人体模型和生物动力学模型的使用导致了代码之间存在可理解的差异。先前的模型保留在新代码中,其结果与先前代码中的结果相同。OLINDA/EXM 2.0代表了从版本1的升级,采用了国际社会推荐的新建模数据。它对放射性药物临床试验中的剂量评估、现有药物的理论计算、教学及其他目的的内部剂量计算进行了标准化。