Department of Interventional Medicine, Naval General Hospital, Beijing, China (mainland).
Department of Radiology, General Hospital of PLA, Beijing, China (mainland).
Med Sci Monit. 2017 Sep 10;23:4366-4375. doi: 10.12659/msm.902105.
BACKGROUND The aim of this study was to investigate the safety and effectiveness of fan-shaped distribution and coaxial puncture technology for radioactive iodine 125 (125I) seed implantation in treatment of lung cancer patients with lung dysfunction. MATERIAL AND METHODS We enrolled and analyzed 33 lung cancer patients with lung dysfunction diagnosed in our hospital from 2013 to 2014 in this study, all of which were implanted with radioactive 125I seed with technology of fan-shaped distribution and coaxial puncture. The matched peripheral dose (MPD) range was 90-140GY. The brachytherapy planning system (TPS) was used to draw up a preoperative seed implantation plan. The fan-shaped distribution system was applied to simulate a surgery program, and seed implantation pitch was 0.5-1.0 cm. Real-time adjustment was necessary during surgery. Dose distributions were verified by TPS immediately after implantation. Intraoperative and postoperative surgery-related complications were analyzed. All patients were followed up for 6 months, and the local control rate of cancer was evaluated through CT scan. RESULTS All patients were operated on successfully. The main surgery-related complications were pulmonary hemorrhage, pleural cavity hemorrhage, and pneumothorax. The local control rates of 2-month, 4-month, and 6-month were 29%, 73%, and 85%, respectively. The total complete remission rate was 18%, the partial response rate was 67%, the stable disease rate was 12%, and the disease progression rate was 3%. CONCLUSIONS The fan-shaped distribution and coaxial puncture technology for radioactive 125I seed implantation was safe and effective in treating lung cancer patients with lung dysfunction.
本研究旨在探讨扇形分布和同轴穿刺技术在放射性碘 125(125I)种子植入治疗肺功能障碍肺癌患者中的安全性和有效性。
我们回顾性分析了 2013 年至 2014 年我院收治的 33 例肺功能障碍肺癌患者,均采用扇形分布和同轴穿刺技术植入放射性 125I 种子。匹配周边剂量(MPD)范围为 90-140GY。使用近距离治疗计划系统(TPS)制定术前种子植入计划。应用扇形分布系统模拟手术方案,种植间距为 0.5-1.0cm,术中需实时调整。植入后立即通过 TPS 验证剂量分布。分析术中及术后与手术相关的并发症。所有患者均随访 6 个月,通过 CT 扫描评估癌症局部控制率。
所有患者均成功手术。主要手术相关并发症为肺出血、胸腔出血和气胸。2 个月、4 个月和 6 个月的局部控制率分别为 29%、73%和 85%。完全缓解率为 18%,部分缓解率为 67%,疾病稳定率为 12%,疾病进展率为 3%。
放射性碘 125 种子植入的扇形分布和同轴穿刺技术治疗肺功能障碍肺癌患者安全有效。