General Surgery Department, Mansoura Faculty of Medicine, Mansoura City, Egypt.
J Gastrointest Surg. 2017 Nov;21(11):1879-1887. doi: 10.1007/s11605-017-3574-z. Epub 2017 Sep 11.
Tridimensional endoanal ultrasonography (3D-EAUS) has been used for the assessment of various anorectal lesions. Previous studies have reported good accuracy of 3D-EAUS in preoperative assessment of fistula-in-ano (FIA). This study aimed to assess the diagnostic utility of 3D-EAUS in preoperative evaluation of primary and recurrent FIA and its role in detection of associated anal sphincter (AS) defects.
Prospectively collected data of patients with FIA who were investigated with 3D-EAUS were reviewed. The findings of EAUS were compared with the intraoperative findings, the reference standard, to find the degree of agreement regarding the position of the internal opening (IO) and primary tract (PT), and presence of secondary tracts using kappa (k) coefficient test. A subgroup analysis was performed to compare the accuracy and sensitivity of EAUS for primary and recurrent FIA.
Of the patients, 131 were included to the study. EAUS had an overall accuracy of 87, 88.5, and 89.5% in detection of IO, PT, and AS defects, respectively. There was very good concordance between the findings of EAUS and intraoperative findings for the investigated parameters (kappa = 0.748, 0.83, 0.935), respectively. Accuracy and sensitivity of EAUS in recurrent FIA were insignificantly lower than primary cases. EAUS detected occult AS defects in 5.3% of the patients studied.
The diagnostic utility of 3D-EAUS was comparable in primary and recurrent FIA. 3D-EAUS was able to detect symptomatic and occult AS defects with higher accuracy than clinical examination.
三维肛门内超声(3D-EAUS)已用于评估各种肛门直肠病变。先前的研究报告称,3D-EAUS 在肛门瘘(FIA)术前评估中的准确性较高。本研究旨在评估 3D-EAUS 在原发性和复发性 FIA 的术前评估中的诊断效用及其在检测相关肛门括约肌(AS)缺陷中的作用。
回顾性收集接受 3D-EAUS 检查的 FIA 患者的前瞻性数据。将 EAUS 结果与术中发现(金标准)进行比较,以发现内部开口(IO)和原发性瘘管(PT)位置以及二次瘘管存在的一致性程度,使用kappa(k)系数检验。进行亚组分析以比较 EAUS 对原发性和复发性 FIA 的准确性和敏感性。
共有 131 例患者纳入本研究。EAUS 在检测 IO、PT 和 AS 缺陷方面的总体准确率分别为 87%、88.5%和 89.5%。EAUS 与术中发现之间在调查参数上具有非常好的一致性(kappa 值分别为 0.748、0.83 和 0.935)。EAUS 在复发性 FIA 中的准确性和敏感性与原发性 FIA 相比无显著差异。EAUS 在 5.3%的研究患者中检测到隐匿性 AS 缺陷。
3D-EAUS 在原发性和复发性 FIA 中的诊断效用相当。3D-EAUS 能够比临床检查更准确地检测出有症状和隐匿性 AS 缺陷。