Reliability of size and echo intensity of abdominal skeletal muscles using extended field-of-view ultrasound imaging.

机构信息

Research Center of Health, Physical Fitness and Sports, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8601, Japan.

Graduate School of Education and Human Development, Nagoya University, 1 Furo-cho, Chikusa-ku, Nagoya, Aichi, 464-8601, Japan.

出版信息

Eur J Appl Physiol. 2017 Nov;117(11):2263-2270. doi: 10.1007/s00421-017-3713-y. Epub 2017 Sep 14.

Abstract

PURPOSE

This study aimed to examine the reliability of extended field-of-view (EFOV) ultrasound imaging to evaluate the cross-sectional area (CSA) and echo intensity of abdominal skeletal muscles.

METHODS

Twenty-seven healthy young males (age 18.6 ± 1.0 years, body mass index 20.9 ± 2.8 kg/m, waist circumference 75.0 ± 7.9 cm, body fat 16.6 ± 5.9%) visited the laboratory on 2 days. EFOV ultrasound images of the rectus abdominis, abdominal oblique, and erector spinae muscles were acquired at the height of the third lumbar vertebra with the subject lying on a bed. We then analyzed CSA and echo intensity using ImageJ software and calculated intra-class correlation coefficients (ICC) and the standard error of measurement (SEM).

RESULTS

No significant differences (p = 0.149-0.679) were observed in CSA or echo intensity values for each skeletal muscle between days. ICC and SEM values in CSA for each skeletal muscle ranged between 0.944 and 0.958 and 4.9% and 7.3%, respectively. The corresponding values for echo intensity were 0.851-0.945 for ICC and 5.3-9.7% for SEM.

CONCLUSIONS

The present results indicate that EFOV ultrasound imaging has high repeatability for measuring CSA and echo intensity of abdominal skeletal muscle groups in healthy college-aged males.

摘要

目的

本研究旨在检验扩展视野(EFOV)超声成像评估腹部骨骼肌横截面积(CSA)和回声强度的可靠性。

方法

27 名健康年轻男性(年龄 18.6±1.0 岁,BMI 20.9±2.8kg/m,腰围 75.0±7.9cm,体脂 16.6±5.9%)在 2 天内到实验室就诊。受检者仰卧于床上,EFOV 超声探头置于第三腰椎水平,获取腹直肌、腹外斜肌和竖脊肌的 CSA 和回声强度图像。采用 ImageJ 软件进行分析,并计算了组内相关系数(ICC)和测量标准误差(SEM)。

结果

各骨骼肌的 CSA 和回声强度值在 2 天内无显著差异(p=0.149-0.679)。各骨骼肌 CSA 的 ICC 和 SEM 值分别在 0.944-0.958 和 4.9%-7.3%之间,回声强度的 ICC 和 SEM 值分别在 0.851-0.945 和 5.3%-9.7%之间。

结论

EFOV 超声成像在测量健康大学生男性腹部骨骼肌群 CSA 和回声强度方面具有高度可重复性。