Suppr超能文献

描述在不稳定板上站立姿势的传统变量和基于熵的变量在组内和组间的可靠性。

Intra- and inter-session reliability of traditional and entropy-based variables describing stance on a wobble board.

作者信息

Bizovska Lucia, Janura Miroslav, Svoboda Zdenek, Cerny Martin, Krohova Jana, Smondrk Maros

机构信息

Department of Natural Sciences in Kinathropology, Faculty of Physical Culture, Palacky University Olomouc, Trida Miru 117, Olomouc 77111, Czech Republic.

Department of Natural Sciences in Kinathropology, Faculty of Physical Culture, Palacky University Olomouc, Trida Miru 117, Olomouc 77111, Czech Republic.

出版信息

Med Eng Phys. 2017 Dec;50:29-34. doi: 10.1016/j.medengphy.2017.08.017. Epub 2017 Sep 12.

Abstract

A wobble board (WB) is a balance rehabilitation tool that is used in physiotherapy to improve strength and stability. The WB tested in this study includes a sensory module for measuring patients' tilt and rotation during stance. The aim of this study was to assess the reliability and validity of a balance measurement using a WB. Thirty healthy young adults participated in this study. The participants stood on the WB to simultaneously record the tilt of the WB and the center of pressure data using a force plate. The data were recorded during five measurement sessions on various days, with four trials each. Sways, velocities and indexes of complexity (CI) were computed. For reliability assessment, we used intra-class correlation coefficients within and between sessions; for validity, we computed Spearman correlation coefficients. The velocities and CI showed good intra-session reliability, and the sways showed mostly poor intra-session reliability. The results of inter-session reliability showed good to excellent reliability for CI, poor reliability for sways and poor to good reliability for velocities. The Spearman correlation coefficient showed excellent agreement between the mean velocities computed from the force plate and the WB. Our results confirm that the WB tested is suitable for stability assessment in young adults.

摘要

摇摆板(WB)是一种平衡康复工具,用于物理治疗以增强力量和稳定性。本研究中测试的摇摆板包括一个用于测量患者站立时倾斜和旋转的传感模块。本研究的目的是评估使用摇摆板进行平衡测量的可靠性和有效性。30名健康的年轻成年人参与了本研究。参与者站在摇摆板上,同时使用测力台记录摇摆板的倾斜度和压力中心数据。在不同日期的五次测量过程中记录数据,每次测量进行四次试验。计算了摇摆度、速度和复杂度指数(CI)。为了进行可靠性评估,我们使用了各次测量之间和测量过程中的组内相关系数;为了评估有效性,我们计算了斯皮尔曼相关系数。速度和CI在测量过程中显示出良好的可靠性,而摇摆度在测量过程中大多显示出较差的可靠性。测量过程之间的可靠性结果显示,CI的可靠性良好至优秀,摇摆度的可靠性较差,速度的可靠性较差至良好。斯皮尔曼相关系数显示,测力台和摇摆板计算出的平均速度之间具有极好的一致性。我们的结果证实,所测试的摇摆板适用于年轻成年人的稳定性评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验