Department of Orthodontics, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Department of Anatomy, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Sci Rep. 2017 Sep 20;7(1):11993. doi: 10.1038/s41598-017-12100-4.
The accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superimposed onto the CBCT images. Condyles were isolated on the CBCT render volume using the surface models as reference and volumes were measured. Linear measurements were made on CBCT slices. The CBCT method was found to be reliable for both volumetric and linear measurements (CV < 3%; CCI > 0.90). Highly accurate values were obtained for the three linear measurements and volume. CBCT is a reliable and accurate method for taking volumetric and linear measurements on mandibular condyles in the presence of soft tissue, and so a valid tool for clinical diagnosis.
锥形束 CT(CBCT)在评估髁突的线性和体积测量的准确性时,仅在干燥颅骨上进行了评估。本研究旨在评估在存在软组织的情况下使用 CBCT 对下颌髁突进行线性和体积测量的可靠性和准确性。本研究使用了 6 具防腐尸体头颅。首先进行 CBCT 扫描,然后取出髁突。使用排水法来计算髁突的体积,并使用数字卡尺进行 3 次线性测量,这些测量用作金标准。使用 3D 扫描仪获取髁突的表面模型,并将其叠加到 CBCT 图像上。使用表面模型作为参考,在 CBCT 渲染体积上隔离髁突,并测量体积。在 CBCT 切片上进行线性测量。结果发现,CBCT 法在体积和线性测量方面均具有可靠性(CV<3%;CCI>0.90)。三个线性测量和体积均获得了高度准确的值。CBCT 是一种在存在软组织的情况下对下颌髁突进行体积和线性测量的可靠且准确的方法,因此是临床诊断的有效工具。