Suppr超能文献

Head-stem trunnion dissociation due to corrosion in total hip arthroplasty.

作者信息

Whitehouse Michael R

机构信息

Musculoskeletal Research Unit, School of Clinical Sciences, Southmead Hospital, Bristol BS10 5NB, UK.

Avon Orthopaedic Centre, Southmead Hospital, North Bristol NHS Trust, Bristol BS10 5NB, UK.

出版信息

Ann Transl Med. 2017 Sep;5(17):363. doi: 10.21037/atm.2017.06.42.

Abstract
摘要

相似文献

1
Head-stem trunnion dissociation due to corrosion in total hip arthroplasty.
Ann Transl Med. 2017 Sep;5(17):363. doi: 10.21037/atm.2017.06.42.
2
Catastrophic Femoral Head-Stem Trunnion Dissociation Secondary to Corrosion.
J Bone Joint Surg Am. 2016 Aug 17;98(16):1400-4. doi: 10.2106/JBJS.15.00914.
3
Gross trunnion failure after a metal-on-polyethylene total hip arthroplasty leading to dissociation at the femoral head-trunnion interface.
Arthroplast Today. 2019 Mar 13;5(1):5-10. doi: 10.1016/j.artd.2019.02.001. eCollection 2019 Mar.
5
Taper-Trunnion Interface Stress Varies Significantly With Head Size and Activity.
J Arthroplasty. 2019 Jan;34(1):157-162. doi: 10.1016/j.arth.2018.09.004. Epub 2018 Sep 22.
6
Will New Metal Heads Restore Mechanical Integrity of Corroded Trunnions?
J Arthroplasty. 2017 Apr;32(4):1356-1359. doi: 10.1016/j.arth.2016.10.007. Epub 2016 Oct 11.
7
Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty.
J Arthroplasty. 2017 Aug;32(8):2574-2579. doi: 10.1016/j.arth.2017.03.012. Epub 2017 Mar 29.
9
There Is No Significant Difference in Fretting and Corrosion at the Trunnion of Metal and Ceramic Heads.
Orthopedics. 2019 Jan 1;42(1):e99-e103. doi: 10.3928/01477447-20181206-03. Epub 2018 Dec 13.

本文引用的文献

1
2
Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.
HSS J. 2017 Feb;13(1):42-49. doi: 10.1007/s11420-016-9526-4. Epub 2016 Sep 20.
4
Catastrophic Femoral Head-Stem Trunnion Dissociation Secondary to Corrosion.
J Bone Joint Surg Am. 2016 Aug 17;98(16):1400-4. doi: 10.2106/JBJS.15.00914.
5
Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability.
Bone Joint Res. 2016 Aug;5(8):338-46. doi: 10.1302/2046-3758.58.BJR-2016-0044.R1.
8
Taperosis: Does head length affect fretting and corrosion in total hip arthroplasty?
Bone Joint J. 2015 Jul;97-B(7):911-6. doi: 10.1302/0301-620X.97B7.35149.
9
Gross trunnion failure after primary total hip arthroplasty.
J Arthroplasty. 2015 Apr;30(4):641-8. doi: 10.1016/j.arth.2014.11.023. Epub 2014 Nov 26.
10
Modular neck femoral stems.
Bone Joint J. 2013 Aug;95-B(8):1011-21. doi: 10.1302/0301-620X.95B8.31525.