文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

作者信息

Chou I-Jun, Lim Su-Yin, Tanasescu Radu, Al-Radaideh Ali, Mougin Olivier E, Tench Christopher R, Whitehouse William P, Gowland Penny A, Constantinescu Cris S

机构信息

Division of Clinical Neuroscience, University of Nottingham, Nottingham, UK.

Division of Academic Child Health, School of Medicine, University of Nottingham, Nottingham, UK.

出版信息

J Neuroimaging. 2018 Mar;28(2):183-190. doi: 10.1111/jon.12474. Epub 2017 Sep 25.


DOI:10.1111/jon.12474
PMID:28944575
Abstract

BACKGROUND AND PURPOSE: Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT ) images in the detection of white matter lesions compared with 3T-FLAIR. METHODS: Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. RESULTS: Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). CONCLUSION: Seven-Tesla MT sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT imaging.

摘要

相似文献

[1]
Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

J Neuroimaging. 2018-3

[2]
A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions.

Invest Radiol. 2009-9

[3]
Comparison of Multiple Sclerosis Cortical Lesion Types Detected by Multicontrast 3T and 7T MRI.

AJNR Am J Neuroradiol. 2019-6-20

[4]
Automated separation of diffusely abnormal white matter from focal white matter lesions on MRI in multiple sclerosis.

Neuroimage. 2020-6

[5]
7T MPFLAIR versus MP2RAGE for Quantifying Lesion Volume in Multiple Sclerosis.

J Neuroimaging. 2020-7

[6]
Focal multiple sclerosis lesions abound in 'normal appearing white matter'.

Mult Scler. 2011-7-25

[7]
Patient-specific 3D FLAIR for enhanced visualization of brain white matter lesions in multiple sclerosis.

J Magn Reson Imaging. 2016-11-21

[8]
Identification of Chronic Active Multiple Sclerosis Lesions on 3T MRI.

AJNR Am J Neuroradiol. 2018-5-3

[9]
Optimal combination of FLAIR and T2-weighted MRI for improved lesion contrast in multiple sclerosis.

J Magn Reson Imaging. 2016-11

[10]
3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions.

J Magn Reson Imaging. 2010-10

引用本文的文献

[1]
Evaluating the role of 7-Tesla magnetic resonance imaging in neurosurgery: Trends in literature since clinical approval.

World J Radiol. 2024-7-28

[2]
Natalizumab Treatment for Relapsing Multiple Sclerosis Stabilises Normal-Appearing White Matter Microstructure: A One-Year Prospective Ultra-High-Field Quantitative Imaging Study.

Brain Sci. 2023-10-17

[3]
MRI with ultrahigh field strength and high-performance gradients: challenges and opportunities for clinical neuroimaging at 7 T and beyond.

Eur Radiol Exp. 2021-8-26

[4]
7T MPFLAIR versus MP2RAGE for Quantifying Lesion Volume in Multiple Sclerosis.

J Neuroimaging. 2020-7

[5]
Reduced Myelin Signal in Normal-appearing White Matter in Neuromyelitis Optica Measured by 7T Magnetic Resonance Imaging.

Sci Rep. 2019-10-7

[6]
Selective Inversion Recovery Quantitative Magnetization Transfer Brain MRI at 7T: Clinical and Postmortem Validation in Multiple Sclerosis.

J Neuroimaging. 2018-7

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索