Suppr超能文献

全髋关节置换术中陶瓷对金属与金属对金属关节面比较的前瞻性随机试验的五年随访

Five-year follow-up of a prospective randomised trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip arthroplasty.

作者信息

Schouten R, Malone A A, Frampton C M, Tiffen C, Hooper G

机构信息

University of Otago, PO Box 4345, Christchurch, New Zealand.

Pacific Radiology, PO Box 130000, Armagh, Christchurch 8141, New Zealand.

出版信息

Bone Joint J. 2017 Oct;99-B(10):1298-1303. doi: 10.1302/0301-620X.99B10.BJJ-2016-0905.R1.

Abstract

AIMS

The primary aim of this independent prospective randomised trial was to compare serum metal ion levels for ceramic-on-metal (CoM) and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty (THA). Our one-year results demonstrated elevation in metal ion levels above baseline with no significant difference between the CoM and MoM groups. This paper reviews the five-year data.

PATIENTS AND METHODS

The implants used in each patient differed only in respect to the type of femoral head (ceramic or metal). At five-year follow-up of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available for comparison.

RESULTS

The mean serum cobalt (Co) and chromium (Cr) ion levels remained above baseline in both groups (CoM: Co 1.16 μg/l (0.41 to 14.67), Cr 1.05 μg/l (0.16 to 12.58); MoM: Co 2.93 μg/l (0.35 to 30.29), Cr 1.85 μg/l (0.36 to 17.00)) but the increase was significantly less in the CoM cohort (Co difference p = 0.001, Cr difference p = 0.002). These medium-term results, coupled with lower revision rates from national joint registries, suggest that the performance of CoM THA may be superior to that of MoM.

CONCLUSION

While both bearing combinations have since been withdrawn these results provide useful information for planning clinical surveillance of CoM THAs and warrants continued monitoring. Cite this article: 2017;99-B:1298-1303.

摘要

目的

本独立前瞻性随机试验的主要目的是比较全髋关节置换术(THA)中陶瓷对金属(CoM)和金属对金属(MoM)关节表面的血清金属离子水平。我们的一年期结果显示,金属离子水平高于基线水平,CoM组和MoM组之间无显著差异。本文回顾了五年期数据。

患者与方法

每位患者使用的植入物仅在股骨头类型(陶瓷或金属)方面有所不同。在对83名入组患者进行五年随访时,有67名患者(36名CoM,31名MoM)的数据可供比较。

结果

两组患者的血清钴(Co)和铬(Cr)离子平均水平均高于基线(CoM组:Co 1.16μg/l(0.41至14.67),Cr 1.05μg/l(0.16至12.58);MoM组:Co 2.93μg/l(0.35至30.29),Cr 1.85μg/l(0.36至17.00)),但CoM队列中的升高明显较少(Co差异p = 0.001,Cr差异p = 0.002)。这些中期结果,再加上国家关节登记处较低的翻修率,表明CoM THA的性能可能优于MoM。

结论

虽然这两种关节组合后来都已停用,但这些结果为规划CoM THA的临床监测提供了有用信息,值得继续监测。引用本文:2017;99-B:1298-1303。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验