Waldstein Wenzel, Koller Ulrich, Springer Bernhard, Kolbitsch Paul, Brodner Wolfram, Windhager Reinhard, Lass Richard
Department of Orthopaedic and Trauma Surgery, Vienna General Hospital, Medical University of Vienna, Vienna, Austria.
Department of Orthopedics, University Hospital Krems, Krems, Austria.
Bone Joint Res. 2020 May 16;9(3):146-151. doi: 10.1302/2046-3758.93.BJR-2019-0218.R1. eCollection 2020 Mar.
Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing.
The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery.
The median cobalt concentration in the MoM group was 1.04 μg/l (interquartile range (IQR) 0.64 to 1.70) at a mean of 21 years (20 to 24) postoperatively and these values were similar (p = 0.799) to cobalt levels at five years. In the CoP control group, the median cobalt levels were below the detection limit (< 0.3 μg/l; median 0.15 μg/l, IQR 0.15 to 0.75) at 20 years. The mean Harris Hip Score was 91.4 points (61 to 100) in the MoM group and 92.8 points (63 to 100) in the CoP group.
This study represents the longest follow-up series evaluating the serum cobalt levels after 28 mm head MoM bearing THA and shows that serum cobalt concentrations remain at low levels at a mean of 21 years (20 to 24) after implantation. 2020;9(3):145-150.
在全髋关节置换术(THA)中引入第二代金属对金属(MoM)关节,以减少与磨损相关的并发症。本研究报告了采用MoM(Metasul)或陶瓷对聚乙烯(CoP)关节进行THA术后至少20年的血清钴水平和临床结果。
本研究是对先前发表的一项前瞻性随机对照研究的更新,评估了100例接受MoM或CoP关节置换的THA患者连续队列的血清钴水平。共有31例患者可进行临床和放射学随访检查。在排除11例因其他含钴植入物的患者后,分析了20例患者(MoM组(n = 11);CoP组(n = 9)),平均年龄69岁(42至97岁)。将血清钴水平与术后五年的血清钴水平进行比较。
MoM组术后平均21年(20至24年)的钴浓度中位数为1.04μg/l(四分位间距(IQR)0.64至1.70),这些值与五年时的钴水平相似(p = 0.799)。在CoP对照组中,20年时钴水平中位数低于检测限(<0.3μg/l;中位数0.15μg/l,IQR 0.15至0.75)。MoM组的平均Harris髋关节评分为91.4分(61至100分),CoP组为92.8分(63至100分)。
本研究是评估28mm股骨头MoM关节置换术后血清钴水平的最长随访系列研究,结果显示植入后平均21年(20至24年)血清钴浓度仍保持在低水平。2020;9(3):145 - 150。